Huawei OSN 8800 03030XEF TN54NS4M03
Brand: Huawei
Part Number : 03030XEF
Model: TN54NS4M03
Detail:The Optix OSN 8800-TN54NS4M03-100Gbit/s line service processing board (4*28G, 700ps/nm, RX1~RX4_PIN, TX1~TX4_-1dBm~+2dBm, (193.2THZ_193.1THZ_193.0THZ_192.9THZ)/(193.25THZ_193. 15THZ_193.05THZ_192.95THZ), LC)
Condition: Brand New Sealed
Availability: IN STOCK
- Description
- Specification
- Ordering information
- Inquiry
Part Number | 03030XEF |
Model | TN54NS4M03 |
Description | Optix OSN 8800-TN54NS4M03-100Gbit/s line service processing board (4*28G, 700ps/nm, RX1~RX4_PIN, TX1~TX4_-1dBm~+2dBm, (193.2THZ_193.1THZ_193.0THZ_192.9THZ)/(193.25THZ_193. 15THZ_193.05THZ_192.95THZ), LC) |
The OptiX OSN 8800 equipments use the same software and hardware platforms and therefore they share most of the boards. However, each of them has its own highlights that address diverse network requirements.
The OptiX OSN 8800 Intelligent Optical Transport Platform (OptiX OSN 8800 for short) is referred to as Huawei next generation intelligent optical transport platform. It is a future-proof product launched to address the IP-based metro network development trend. Using a new architecture, the product supports dynamic optical-layer grooming and flexible electrical-layer grooming. In addition, the product features high integration and reliability and supports multi-service transmission.
Specifications | OptiX OSN 8800 T16 | OptiX OSN 8800 T32 | OptiX OSN 8800 T64 | ||
---|---|---|---|---|---|
Dimensions (mm) | 498 (W) x 295 (D) x 450 (H) | 498 (W) x 295 (D) x 900 (H) | 498 (W) x 580 (D) x 900 (H) | ||
Number of slots for service boards | 16 | 32 | 64 | ||
Switch | Optical | 1 to 9-degree ROADM | |||
Electrical | 1.6T ODUk(k=0, 1, 2, 2e, 3, 4, flex) 640G VC-4 and 20G VC-3/VC-12 800G Packet | Enhanced subrack: 3.2T ODUk(k=0, 1, 2, 2e, 3, 4, flex) 1.28T VC-4 and 80G VC-3/VC-12 1.6T Packet General subrack: 1.28T ODUk(k=0, 1, 2, 2e, 3, flex) 1.28T VC-4 and 80G VC-3/VC-12 | Enhanced subrack: 6.4T ODUk(k=0, 1, 2, 2e, 3, 4, flex) 1.28T VC-4 and 80G VC-3/VC-12 General subrack: 2.56T ODUk(k=0, 1, 2, 2e, 3, flex) 1.28T VC-4 and 80G VC-3/VC-12 |
||
Wavelength (max) | DWDM: 80-ch, CWDM: 8-ch | ||||
Wavelength range | DWDM: 1529.16 nm to 1560.61 nm (Band-C, ITU-T G.694.1) CWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2) |
||||
Max. rate per channel | 100Gbit/s (OTU4) | ||||
Max. distance | Multi-span transmission (without electrical regeneration): 32 span x 22 dB/span (10G), 25 span x 22 dB/span (40G), 20 span x 22 dB/span (100G) Ultra-long single-span transmission: 1 span x 81 dB/span (10G), 1 span x 71 dB/span (40G) |
||||
Service types supported | SDH, SONET, Ethernet, SAN, OTN, Video | ||||
Line rate | 2.5 Gbit/s, 10 Gbit/s, 40 Gbit/s, 100 Gbit/s | ||||
Max. capacity per PID group | 200 Gbit/s | ||||
Topology | Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring and mesh | ||||
Redundancy and Protection | Network level protection (OTN) | Optical line protection, intra-board 1+1 protection, client 1+1 protection, ODUk SNCP, tributary SNCP, SW SNCP, ODUk SPRing protection, OWSP | |||
Network level protection (OCS) | Linear MSP, MSP ring, transoceanic MSP ring, SNCP, SNCTP | ||||
Network level protection (Ethernet and packet) | DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, PW APS, STP and RSTP, Tunnel APS, VLAN SNCP | DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, PW APS, STP and RSTP, Tunnel APS, VLAN SNCP | DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, STP and RSTP, VLAN SNCP | ||
Equipment level protection | Power redundancy, fan redundancy, cross-connect board redundancy, system control and communication board redundancy, centralized clock board redundancy, AUX Board 1+1 Redundancy | ||||
Optical power management | ALS, AGC, ALC, APE, IPA, OPA | ||||
Synchronization | Synchronous Ethernet clock IEEE 1588v2 2 Mbit/s or 2 MHz (with the SSM function), ITU-T G.703-compliant external clock source External time source (1PPS+TOD) |
||||
ASON | An OTN network supports the Optical-Layer ASON and electrical-Layer ASON. An OCS network supports the SDH ASON feature. |
||||
Operation Environment | Subrack temperature: Long-term operation: 5°C (41 °F) to 45°C (113 °F) Short-term operation: -5°C (23 °F) to 55°C (131 °F) Relative humidity: Long-term operation: 5% to 85% Short-term operation: 5% to 90% |
Part Number : 03030XEF
Model: TN54NS4M03
Detail:The Optix OSN 8800-TN54NS4M03-100Gbit/s line service processing board (4*28G, 700ps/nm, RX1~RX4_PIN, TX1~TX4_-1dBm~+2dBm, (193.2THZ_193.1THZ_193.0THZ_192.9THZ)/(193.25THZ_193. 15THZ_193.05THZ_192.95THZ), LC)
Condition: Brand New Sealed
Availability: IN STOCK