Huawei OptiX OSN 9800 TNU2UXCS Board

$5,600.00 $3,600.00

Brand: Huawei

Model: TNU2UXCS

Detail: Huawei Core OTN-TNU2UXCS- cross-connect board-1*1

Condition: 100% New

Availability: IN STOCK

  • Description
  • Features
  • Ordering information
  • Inquiry

OptiX OSN 9800 TNU2UXCS Board

UXCS board is a cross-connect board. The M:N mode is used to configure UXCS boards. M represents the number of protection UXCS boards, and N represents the number of working UXCS boards.

 

 

UXCS

UXCS: Enhanced Universal Cross Connect Board

Version Description

The UXCS board has two functional version:TNU2, TNS1 .

Mapping Between the Board and OptiX OSN 9800 U64/U32/U16

The following provides the board(s) supported by the OptiX OSN 9800 U64/U32/U16. However, the availability of the board(s) is subject to PCNs. For PCN information, contact the product manager at your local Huawei office.

Board Initial Version 9800 U64 StandardSubrack 9800 U32 StandardSubrack 9800 U16 Subrack
TNU2UXCS V100R002C10&V100R002C00SPC810 Y Y N
TNS1UXCS V100R002C10&V100R002C00SPC810 N N Y
 NOTE:

The logical board of the XCS and UXCS cannot be used in the same subrack.

Variant

The TNU2UXCS board has only one variant: TNU2UXCS01.

The TNS1UXCS board has only one variant: TNS1UXCS01.

Differences Between Versions
  • Appearance:The UXCS panel appearance varies according to the version. For details
  • Specifications:
  • The UXCS specifications vary according to the version. For details, see UXCS Specifications.
Substitution Relationship

Original Board Substitute Board Substitution Rules
TNU2UXCS None -
TNV2XCS TNU2UXCS The TNU2UXCS can be created as V2XCS on the NMS. The former can substitute for the latter, without any software upgrade. After substitution, the TNU2UXCS functions as the TNV2XCS.
TNS1XCS TNS1UXCS The TNS1UXCS can be created as S1XCS on the NMS. The former can substitute for the latter, without any software upgrade. After substitution, the TNS1UXCS functions as the TNS1XCS.
TNS1UXCS None -

Update Description

This section describes the hardware updates in V100R002C10&V100R002C00SPC810 and later versions as well as the reasons for the updates. Any product versions that are not listed in the document means that they have no hardware updates.

Hardware Updates in V100R002C10&V100R002C00SPC810

Hardware Update Reason for the Update
Added the TNU2UXCS and TNS1UXCS board. The TNU2UXCS and TNS1UXCS board must be used to cross-connect and protect ODUk (k = 0, 1, 2, 2e, 3, 4, flex) signals ,packet services and VC-4 signals in a subrack.

Application

UXCS board is a cross-connect board. The M:N mode is used to configure UXCS boards. M represents the number of protection UXCS boards, and N represents the number of working UXCS boards. The working and protection UXCS boards are used to cross-connect and protect ODUk (k = 0, 1, 2, 2e, 3, 4, or flex) signals, Ethernet packets and VC-4 signals inside a subrack.

the position of the UXCS board in a WDM system.

Figure 8-153  Position of the UXCS board in a WDM system

Functions and Features

The UXCS board performs centralized cross-connections of electrical signals.

describes the functions and features of the UXCS board.

Table 8-189  Functions and features of the UXCS board

Function and Feature Description
Basic function Performs centralized cross-connections of ODUk (k = 0, 1, 2, 2e, 3, 4, or flex) signals, Ethernet packets and VC-4 signalsinside the subrack.
Configuration and cross-connect capacity
OptiX OSN 9800 U64 Standard subrack (Only supported by the TNU2UXCS board )

  • Cross-connects a maximum of 25.6 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4 or flex) signals.
  • Performs packet switching of a maximum of 12.8 Tbit/s Ethernet services.
  • Cross-connects a maximum of 5.12 Tbit/s VC-4 signals.
  • Each service slot provides a cross-connect capacity of 400 Gbit/s.
OptiX OSN 9800 U32 Standard subrack (Only supported by the TNU2UXCS board )

  • Cross-connects a maximum of 12.8 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4 or flex) signals.
  • Performs packet switching of a maximum of 6.4 Tbit/s Ethernet services.
  • Cross-connects a maximum of 2.56 Tbit/s VC-4 signals.
  • Each service slot provides a cross-connect capacity of 400 Gbit/s.
OptiX OSN 9800 U16 subrack (Only supported by the TNS1UXCS board )

  • Cross-connects a maximum of 5.6 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4 or flex) signals.
  • Performs packet switching of a maximum of 2.8 Tbit/s Ethernet services.
  • Cross-connects a maximum of 1.12 Tbit/s VC-4 signals.
  • Each service slot provides a cross-connect capacity of 400 Gbit/s.
Backup mode The M:N mode is used to configure UXCS boards. M represents the number of protection UXCS boards, and N represents the number of working UXCS boards.

  • For the OptiX OSN 9800 U64 Standard: M + N = 14, M ≤ 2.
  • For the OptiX OSN 9800 U32 Standard/U16: M + N = 7, M ≤ 2.

When two UXCS boards are faulty, the system can still function properly. If more than two UXCS boards become faulty, however, the system will fail.

Switching mode
  • Auto switching, manual switching, and forced switching are supported.
  • Revertive switching is supported.
  • An UXCS board can be locked in a working or protection state.
Electrical-layer ASON Supported

Front Panel

There are four indicators on the front panel of the UXCS board.

Appearance of the Front Panel

shows the front panel of the TNU2UXCS board.

Figure 8-154  Front panel of the TNU2UXCS board

shows the front panel of the TNS1UXCS board.

Figure 8-155  Front panel of the TNS1UXCS board
Indicators

Four indicators are present on the front panel:

  • Board hardware status indicator (STAT) - triple-colored (red, green, yellow)
  • Service active status indicator (ACT) - dual-colored (red, green)
  • Board software status indicator (PROG) - dual-colored (red, green)
  • Service alarm indicator (SRV) - triple-colored (red, green, yellow)

For details about these indicators, see Board Indicators.

Interfaces

The UXCS board has no external interfaces.

Valid Slots

The UXCS board is a single-width board (requiring one slot).

lists the valid slots for the TNU2UXCS board.

Table 8-190  Valid slots for the TNU2UXCS board

Product Valid Slots
OptiX OSN 9800 U32 Standardsubrack IU71-IU77
OptiX OSN 9800 U64 Standardsubrack IU71-IU77, IU79-IU85
lists the valid slots for the TNS1UXCS board.

Table 8-191  Valid slots for TNS1UXCS board

Product Valid Slots
OptiX OSN 9800 U16 subrack IU71-IU77

UXCS Specifications

Specifications include dimensions, weight, and power consumption.

Mechanical Specifications
  • Dimensions of the front panel:TNU2UXCS: Dimensions of the front panel (H x W x D): 477.3 mm (18.8 in.) x 30.5 mm (1.2 in.) x 220.0 mm (8.7 in.)

    TNS1UXCS: Dimensions of the front panel (H x W x D): 183 mm (7.2 in.) x 30.5 mm (1.2 in.) x 220.0 mm (8.7 in.)

  • Weight:TNU2UXCS: 3.06 kg (6.83 lb.)

    TNS1UXCS: 2 kg (4.46 lb.)

Power Consumption

Board Typical Power Consumption (W) Maximum Power Consumptiona (W)
TNU2UXCS 155 165
TNS1UXCS 68 72
a:The maximum power consumption is the power consumed by the board when it works normally under the highest ambient temperature.

Model: TNU2UXCS

Detail: Huawei Core OTN-TNU2UXCS- cross-connect board-1*1

Availability:  IN STOCK