Huawei OSN 7500
Brand: Huawei
Model:OptiX OSN 7500
Detail:The OptiX OSN 7500 Service type supported SDH, PDH, ATM, CES, Ethernet , PCM, SAN, video and others .
Condition: Brand New Sealed
Availability: IN STOCK
- Description
- Specification
- Ordering information
- Inquiry
OSN 7500 is a new-generation optical transmission system developed by Huawei based on the current applications and development trend of MANs. It is an optical core switching (OCS) device applied to service scheduling nodes at the backbone layer of MANs to schedule and transmit services of different types and granularities.
OSN 7500 adopts a unified switching architecture and can function as an MPLS/MPLS-TP-based packet device or a TDM device. When working with other devices of Huawei, OSN 7500 supports various networking modes, including the pure packet mode, hybrid networking (packet + TDM) mode, and pure TDM mode, achieving optimal processing for packet services and traditional SDH services.
In TDM mode, OSN 7500 supports 360 Gbit/s higher order cross-connect capacity and 40 Gbit/s lower order cross-connect capacity. In packet mode, OSN 7500 supports 160 Gbit/s packet switching capacity.
OptiX OSN 7500 features as below :
1.Unified switching architecture
OptiX OSN series products use a unified switching architecture, which can meet the requirements of conventional services and mushrooming packet services.
2.Support for 3G/LTE mobile backhaul
OSN 7500 provides a comprehensive solution for 3G/LTE mobile backhaul based on its packet domain to achieve convergence and scheduling of wireless services at the core layer.
3.Built-in WDM technology enabling flexible networking
OSN 7500 uses the built-in WDM technology to transmit several wavelengths over an optical fiber. This feature allows OSN 7500 to interconnect with WDM equipment to achieve flexible networking.
4.TP-assist, care-free maintenance
The TP-assist implements care-free maintenance solutions for packet transport networks (PTNs) based on the MPLS/MPLS-TP architecture. The OSN 7500 provides a planning tool for PTNs, which enables end-to-end visible service configuration of media gateways and instrument-free site deployment. Moreover, the OSN 7500 supports automatic fault locating and performance monitoring of packet services.
Indicator and Specifications | OSN 7500 Description | OSN 7500 II Description | |
---|---|---|---|
Dimensions (H x W x D) | 756.7 x 496.4 x 295 mm | 800 x 496 x 295 mm | |
Number of valid slots | 22 for processing boards and 8 for interface boards | 16 for processing boards and 16 for interface boards | |
Equipment capacity | Packet | 160 Gbit/s | 320 Gbit/s |
OTN | 560 Gbit/s cross-connections | ||
TDM | 360 Gbit/s higher order cross-connections and 40 Gbit/s lower order cross-connections | 360 Gbit/s higher order cross-connections and 40 Gbit/s lower order cross-connections | |
Service type supported | SDH, PDH, ATM, CES, Ethernet , PCM, SAN, video and others | SDH, PDH, ATM, CES, Ethernet, PCM, video, OTN, and others | |
Smart line board | HSNS3: 40 Gbit/s for a single optical port | HUNS3: 40 Gbit/s for a single optical port HUNQ2: 10 Gbit/s for a single optical port HSNQ2: 10 Gbit/s for a single optical port |
|
Network topology | Point-to-point, chain, star, ring, ring with chain, intersecting rings, tangent rings | Point-to-point, chain, star, ring, ring with chain, intersecting rings, tangent rings | |
Backup and protection | Network-level protection (packet) | Tunnel 1:1/1+1 APS, PW 1:1/1+1 APS, packet linear MSP, LPT, MSTP, MRPS | Tunnel 1:1/1+1 APS, PW 1:1/1+1 APS, packet linear MSP, LPT, MSTP, MRPS |
Network-level protection (TDM) | SDH protection: subnet connection protection, linear MSP, ring MSP, DNI protection, E1 SNCP, shared-fiber virtual path protection, optical-path-shared MSP EoS protection: LCAS, LPT, STP/RSTP, MSTP, ERPS, RPR, VP-Ring/VC-Ring protection | SDH protection: subnet connection protection, linear MSP, ring MSP, DNI protection, E1 SNCP, optical-path-shared MSP EoS protection: LCAS, LPT, STP/RSTP, MSTP, ERPS |
|
Network-level protection (OTN) | Tributary SNCP and ODUk SNCP | ||
Device-level protection | Packet: LAG, MC-LAG TDM: TPS, BPS, PPS, LAG, DLAG, 1+1 protection for ATM boards, 1+1 protection for wavelength conversion units 1+1 hot backup for cross-connect and timing units 1+1 hot backup for SCC units 1+1 hot backup for power input units 1:N protection for +3.3 V power supply of the board Intelligent fan Board protection modes under abnormal conditions | Packet: LAG, MC-LAG TDM: TPS, BPS, PPS, LAG, DLAG 1+1 hot backup for cross-connect and timing units 1+1 hot backup for SCC units 1+1 hot backup for power input units 1:N protection for +3.3 V power supply of the board Intelligent fan Board protection modes under abnormal conditions |
|
Maintenance | MPLS OAM | CV, FFD, BDI, FDI, Ping, Traceroute | CV, FFD, BDI, FDI, Ping, Traceroute |
MPLS-TP OAM | CC, RDI, AIS, LB, LT, LM (only single-ended LM), DM, TST, LCK, CSF (only PW CSF) | CC, RDI, AIS, LB, LT, LM (only single-ended LM), DM, TST, LCK, CSF (only PW CSF) | |
ETH OAM (packet) | Ethernet service OAM: CC, LB, LT, LM (only single-ended LM), DM (only two-way DM) Ethernet port OAM: OAM auto-discovery, link performance monitoring, remote loopback, fault detection, self-loop detection | Ethernet service OAM: CC, LB, LT, LM (only single-ended LM), DM (only two-way DM) Ethernet port OAM: OAM auto-discovery, link performance monitoring, remote loopback, fault detection, self-loop detection |
|
ETH OAM (TDM) | Ethernet service OAM: CC, LB, LT, OAM_Ping Ethernet port OAM: OAM auto-discovery, link performance monitoring, remote loopback, fault detection, self-loop detection | Ethernet service OAM: CC, LB, LT, OAM_Ping Ethernet port OAM: OAM auto-discovery, link performance monitoring, remote loopback, fault detection, self-loop detection |
|
Synchronization | Packet | Physical-layer clock Synchronous Ethernet IEEE 1588v2 CES ACR | Physical-layer clock Synchronous Ethernet IEEE 1588v2 CES ACR |
OTN | Physical-layer clock Synchronous Ethernet |
||
TDM | Physical-layer clock | Physical-layer clock | |
DCN | Outband DCN | HWECC, IP over DCC, OSI over DCC | HWECC, IP over DCC, OSI over DCC |
Inband DCN | HWECC, IP | HWECC, IP | |
TP-Assist | Service configuration: supports end-to-end service configuration and automatic deployment of alarm management. Service commissioning: supports the one-click service connectivity test, one-click service performance test, and automatic test without any instrument. Routine maintenance: supports performance statistics and monitoring and E-Line and E-LAN service path visualization. Fault diagnosis: supports intelligent fault locating, IP ping initiation response, and service loopback detection. | Service configuration: supports end-to-end service configuration and automatic deployment of alarm management. Service commissioning: supports the one-click service connectivity test, one-click service performance test, and automatic test without any instrument. Routine maintenance: supports performance statistics and monitoring and E-Line and E-LAN service path visualization. Fault diagnosis: supports intelligent fault locating, IP ping initiation and response, and service loopback detection. |
|
Standard working voltage | If the standard voltage of the input power is -48 V, the power voltage ranges from -38.4 V to -57.6 V. If the standard voltage of the input power is -60 V, the power voltage ranges from -48 V to -72 V. | If the standard voltage of the input power is -48 V, the power voltage ranges from -38.4 V to -57.6 V. If the standard voltage of the input power is -60 V, the power voltage ranges from -48 V to -72 V. |
|
Installation method | ETSI cabinet | ETSI cabinet | |
Equipment running environment | Subrack temperature | Long-time operation: 0ºC to 45ºC Short-time operation: -5ºC to +55ºC | Long-time operation: 0ºC to 45ºC Short-time operation: -5ºC to +55ºC |
Subrack humidity (relatively) | Long-time operation: 5-85% Short-time operation: 5-95% | Long-time operation: 5-85% Short-time operation: 5-95% |
|
Reliability specifications | System availability | 0.999997487 | 0.999997487 |
Mean time to resolution (MTTR) | 1 h | 1 h | |
Mean time between failures (MTBF) | 45.42 years | 45.42 years |
Model:OSN 7500
Detail:The OptiX OSN 7500 Service type supported SDH, PDH, ATM, CES, Ethernet , PCM, SAN, video and others .
Condition: Brand New Sealed
Availability: IN STOCK