Huawei FusionServer RH5885H V3
Brand: Huawei
Model: FusionServer RH5885H V3 Rack Server
Detail: Huawei FusionServer RH5885H V3 Rack Server, Intel Xeon Intel Xeon E7 V2 or V3 series CPU, 96 DDR4 DIMMs, RAID, Energy efficiency, 5 hot-swappable fan modules, 2 hot-swappable power supplies
Condition: Brand New Sealed
Availability: IN STOCK
- Description
- Specification
- Ordering information
- Inquiry
The RH5885H V3 rack server (labeled as H58H-03 on the nameplate, RH5885H V3 for short) is a general-purpose 4 U four-socket rack server launched by Huawei to meet customer requirements for the Internet, Internet data center (IDC), cloud computing, enterprise, and telecom service applications.
The RH5885H V3 features high computing performance, large storage capacity, low energy consumption, high reliability, and easy deployment and management. With these features, the RH5885H V3 is suited for high-performance computing (HPC), databases, virtualization, basic enterprise applications, and telecommunication service applications.
The RH5885H V3 supports the following hard disk configurations:
- RH5885H V3 (8 hard disks)Supports eight front 2.5-inch SAS HDDs, SATA HDDs, or SSDs.
- RH5885H V3 (12 hard disks)Supports eight front 2.5-inch SAS HDDs, SATA HDDs, or SSDs and four front 2.5-inch NVMe PCIe SSDs
- RH5885H V3 (23 hard disks)Supports twenty-three front 2.5-inch SAS HDDs, SATA HDDs, or SSDs.
PCIe Slot | CPU | PCIe Standard | Connector Bandwidth | Bus Width | Port Number | Bus/Device/Function Number (B/D/F) | Slot Size |
---|---|---|---|---|---|---|---|
Slot 1 | CPU 1 | PCIe 3.0 | x8 | x4 | Port2C | 0/2/2 | Full-height full-length |
Slot 2 | CPU 2 | PCIe 3.0 | x8 | x8 | Port3C | 40/3/2 | Full-height full-length |
Slot 3 | CPU 2 | PCIe 3.0 |
|
Port3A | 40/3/0 | Full-height full-length | |
Slot 4 | CPU 2 | PCIe 2.0 | x8 | x4 | Port0A | 40/0/0 | Full-height full-length |
Slot 5 | CPU 2 | PCIe 3.0 | x8 | x8 | Port2A | 40/2/0 | Full-height full-length |
Slot 6 | CPU 2 | PCIe 3.0 |
|
|
|
Full-height full-length | |
Slot 7 | CPU 1 | PCIe 3.0 | x8 | x4 | Port2D | 0/2/3 | Full-height full-length |
Slot 8 | CPU 3 | PCIe 3.0 | x8 | x8 | Port2C | 80/2/2 | Full-height full-length |
Slot 9 | CPU 3 | PCIe 3.0 |
|
Port2A | 80/2/0 | Full-height full-length | |
Slot 10 | PCH | PCIe 2.0 | x8 | x4 | Port0 | 0/1C/4 | Full-height full-length |
Slot 11 | CPU 3 | PCIe 3.0 | x8 | x8 | Port3A | 80/3/0 | Full-height full-length |
Slot 12 | CPU 3 | PCIe 3.0 |
|
|
|
Full-height full-length | |
Note 1: All slots support full-height full-length PCIe cards and are backward compatible with half-height half-length PCIe cards.
Note 2: All slots support PCIe cards of 75 W or higher power, depending on the PCIe card model. A GPU is preinstalled with two additional power cables for sufficient power. Note 3: If CPUs are not in full configuration or a PCIe card with a PCI bridge is configured, the values of B/D/F may differ. |
Item | RH5885H V3 Specifications | RH5885 V3 Specifications |
---|---|---|
Chassis | Houses and protects all components. | Houses and protects all components inside. |
PCIe card | Installed on a PCIe riser card Supported PCIe cards: PCIe 2.0 x4, PCIe 2.0 x8, PCIe 2.0 x16, PCIe 3.0 x4, PCIe 3.0 x8, and PCIe 3.0 x16 | Three PCIe 3.0 x8 standard slots and one PCIe 2.0 x4 standard slot on the mainboard |
PCIe riser card (supporting non-hot-swappable PCIe cards) | Two types of PCIe riser cards: PCIe x8 riser card: four standard PCIe 3.0 x8 slots, one standard PCIe 3.0 x4 slot, and one standard PCIe 2.0 x4 slot PCIe x16 riser card: two standard PCIe 3.0 x16 slots, one standard PCIe 3.0 x4 slot, and one standard PCIe 2.0 x4 slot | Provides one standard PCIe 3.0 x16 slot and two standard PCIe 3.0 x4 slots. |
Battery tray | Secures and supports an integrated battery backup unit (iBBU) or a supercapacitor. | Secures and supports an iBBU or a supercapacitor. |
Integrated battery backup unit (iBBU) | Provides power failure protection. | Provides power failure protection for a RAID controller card. |
Supercapacitor | A supercapacitor is required to provide power failure protection. | Provides power failure protection for a RAID controller card. |
RAID controller card | Supports RAID levels, RAID level migration, and RAID configuration memory. Supported chips: LSISAS2208, LSISAS2308, LSISAS3008, and LSISAS3108 | Supports multiple RAID levels, RAID level migration, and RAID configuration memory. Supported chips: LSISAS2208, LSISAS2308, LSISAS3008, and LSISAS3108 |
Mainboard | Integrates and interconnects components. Integrates the display chip and provides 16 MB display memory. The maximum resolution is 1024 x 768. The server chipset is the Platform Controller Hub (PCH) using the Intel® C602-J chipset. | Integrates and interconnects components. Display chip integrated into the mainboard Video RAM: 16 MB Maximum resolution: 1024 x 768 Chipset used by the Platform Controller Hub (PCH): Intel® C602-J |
CPU | Connects to the other three CPUs through two-way 20-lane QuickPath Interconnects (QPIs) at a speed of up to 9.6 GT/s and a two-way bandwidth of 38.4 GB/s. Number of CPUs: two or four CPU models: Intel® Ivy Bridge-EX® E7-4800 v2 or E7-8800 v2 Intel® Haswell-EX® E7-4800 v3 or E7-8800 v3 Intel® Broadwell-EX® E7-4800 v4 or E7-8800 v4 | Connects to the other three CPUs through two-way 20-lane QuickPath Interconnects (QPIs) at a speed of up to 9.6 GT/s and a two-way bandwidth of 38.4 GB/s. Two or four Intel® Haswell-EX® E7-4800 v3 or E7-8800 v3 series CPUs for an RH5885 V3 with E7 v3 CPUs and DDR3 DIMMs |
Heat sink | Cools a CPU and supports fool-proof design. | Cools a CPU and adopts foolproof design. Each CPU is configured with one heat sink. |
DIMM | DDR3 DIMMs: Capacity per DIMM: up to 32 GB Total capacity: up to 3 TB Memory bus frequency: 1066 MHz, 1333 MHz, or 1600 MHz DDR4 DIMMs: Capacity per DIMM: up to 64 GB Total capacity: up to 6 TB Memory bus frequency: 1333 MHz, 1600 MHz, or 1866 MHz | Up to 48 DDR3 DIMMs for an RH5885 V3 with E7 v3 CPUs and DDR3 DIMMs: Maximum capacity per DIMM: 32 GB Maximum total capacity: 1.5 TB |
Hard disk backplane | Provides power and data transmission channels for hard disks. The RH5885H V3 supports three types of hard disk backplanes for connecting to the following hard disks, respectively: Eight SAS HDDs, SATA HDDs, or SSDs Eight SAS HDDs, SATA HDDs, or SSDs and four NVMe PCIe SSDs Twenty-three SAS HDDs, SATA HDDs, or SSDs | Supplies power to hard disks and provides data transmission channels. The RH5885 V3 supports two types of hard disk backplanes for connecting to 8 or 23 hard disks, respectively. |
DVD drive | Installs operating systems (OSs). | Installs operating systems (OSs). |
Hard disk | Stores data for the RH5885H V3. SAS HDDs, SATA HDDs, and SSDs support hot swap, and NVMe PCIe SSDs support orderly hot swap. Supported hard disk configurations: 8-bay server: up to eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs 12-bay server: up to eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs and four 2.5-inch NVMe PCIe SSDs 23-bay configuration: up to twenty-three 2.5-inch SAS HDDs, SATA HDDs, or SSDs | Stores data for the RH5885 V3 and supports hot swap. Supported hard disk configurations: 8-bay server: up to eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs 23-bay configuration: up to twenty-three 2.5-inch SAS HDDs, SATA HDDs, or SSDs |
Fan module | Dissipate heat from the server, support hot swap, and allow one-fan failures. If one fan fails, the speed of the other fans is adjusted by area to ensure heat dissipation. | Dissipates heat from the server, supports hot swap, and allows one-fan failures. A faulty fan will trigger speed adjustment of other fans by area, maintaining heat dissipation. |
(Optional) Front bezel | The component is optional and can be selected as required. Protects the server front panel. | The component is optional and can be selected as required. Protects the server front panel. |
NIC | One GE NIC with two or four GE ports One 10GE NIC with two 10GE ports Both NICs support Network Controller Sideband Interface (NC-SI). | One GE NIC with two or four GE ports One 10GE NIC with two 10GE ports Both NICs support Network Controller Sideband Interface (NC-SI). |
PCIe riser card (supporting hot-swappable PCIe cards) | Provides four standard PCIe 3.0 x8 slots for PCIe cards that can be hot-swapped without opening the chassis cover. | |
BMC card | contains the baseboard management controller (BMC). It manages the server, including powering on or off the server, obtaining slot IDs, inspecting power supplies, implementing KVM over IP, and providing the black box function. | Manages the RH5885 V3. |
Model: FusionServer RH5885H V3 Rack Server
Detail: Huawei FusionServer RH5885H V3 Rack Server, Intel Xeon Intel Xeon E7 V2 or V3 series CPU, 96 DDR4 DIMMs, RAID, Energy efficiency, 5 hot-swappable fan modules, 2 hot-swappable power supplies
Condition: Brand New Sealed
Availability: IN STOCK