Huawei E9000

Brand: Huawei

Model:Tecal E9000

Detail: Huawei Tecal E9000 Server,configured with Compute Nodes: CH121 V3,CH140 V3,CH220 V3,CH222 V3,CH226 V3,CH242 V3,CH121 V2,CH140 V2,CH220 V2,CH221 V2,CH222 V2,CH240 V2,CH242 V2

Condition: Brand New Sealed

Availability: IN STOCK

  • Description
  • Specification
  • Ordering information
  • Inquiry

The E9000 is model of chassis product that Huawei developed. It can house the E9000 series compute nodes, storage nodes, and resource expansion nodes in its 12 U chassis.

The E9000 has the following features and functions:

  • Supports 8 full-width compute nodes or 16 half-width compute nodes for flexible slot configuration.
  • Supports a compute node with 2 CPUs and 24 DIMMs or 2 x (2 CPUs + 8 DIMMs) in a half-width slot.
  • Supports a compute node with 4 CPUs and 48 DIMMs in a full-width slot.
  • Supports the computing density of 64 CPUs/1408 cores per chassis.
  • Supports a maximum memory capacity of 24 TB per chassis.
  • Supports the maximum switching capability (throughput) of 32 Tbit/s for midplane.
  • Provides 4 switch modules (2 pairs), supporting Ethernet, fiber channel (FC), fiber channel over Ethernet (FCoE), InfiniBand switching and I/O ports.
  • Each chassis is configured with two management modules in active/standby mode. They support active/standby switchover, hot swap, and the protocols of Intelligent Platform Management Interface 2.0 (IPMI 2.0), Simple Network Management Protocol (SNMP) v3, SNMP Trap v1, SNMP Trap v2c, SNMP Trap v3, Secure Sockets Layer (SSL), Secure Shell (SSH), Secure File Transfer Protocol (SFTP), Hypertext Transfer Protocol Secure (HTTPS), Network Time Protocol (NTP), Domain Name Service (DNS), Lightweight Directory Access Protocol (LDAP), and Simple Mail Transfer Protocol (SMTP).
  • A display is installed in the front lower part of the chassis. The display is used to set the basic chassis information and monitor the status of the chassis and components in the chassis.

E9000

Item E9000 Specifications
Dimensions (H x W x D)Chassis: 530.2 mm (12U) x 442 mm x 840 mm (20.87 in. x 17.40 in. x 33.07 in.)
PSU: 40.5 mm x 126 mm x 285 mm (1.59 in. x 4.96 in. x 11.22 in.)
Fan module: 84 mm x 82 mm x 296.3 mm (3.31 in. x 3.23 in. x 11.66 in.)
Rack dimensions (H x W x D)For a 1200 mm (47.24 in.) deep cabinet, the minimum internal width of the cabinet is greater than 473 mm (18.62 in.); the distance between the front rack rail and the front inner side is 65 mm (2.56 in.) to 115 mm (4.53 in.); the distance between the front and rear mounting bars is from 689 mm (27.13 in.) to 929 mm (36.57 in.). The recommended guide rail is 21240817, which does not occupy extra space.
For a 1100 mm (43.31 in.) deep cabinet, the minimum internal width of the cabinet is greater than 473 mm (18.62 in.); the distance between the front rack rail and the front inner side is 65 mm (2.56 in.) to 115 mm (4.53 in.); the distance between the front and rear mounting bars is from 689 mm (27.13 in.) to 929 mm (36.57 in.). The recommended guide rail is 21240817, which does not occupy extra space.
For a 1000 mm (39.37 in.) deep cabinet, the minimum internal width of the cabinet is greater than 449 mm (17.68 in.); the distance between the front rack rail and the front inner side is 65 mm (2.56 in.) to 115 mm (4.53 in.); the distance between the front and rear mounting bars is from 500 mm (19.69 in.) to 858 mm (33.78 in.). The recommended guide rail is 21241598, which occupies 1 U space.
ColorBlack
WeightNet:
Empty chassis (including midplane): 70 kg (154.32 lb)
Fully configured chassis: ≤ 230 kg (507.06 lb)
Packing materials:
Chassis packing materials: 30 kg (66.15 lb)
Half-width node packing materials: 2.3 kg (5.07 lb)
Full-width node packing materials: 3.6 kg (7.94 lb)
The weight of a rack without any chassis is about 200 kg (441.00 lb). A rack occupies an area of 1.44 m² (15.50 ft²). The following lists requirements for the floor bearing capacity based on the weight of a rack that has different chassis configurations:
One E9000 chassis: 347.2 kg/m²
Two E9000 chassis: 555.5 kg/m²
Three E9000 chassis: 763.9 kg/m²
TemperatureServer:
Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant)
Storage temperature: -40°C to +65°C (-40°F to +149°F)
Temperature change rate: < 20°C/h (36°F/h)/h
PSU:
Operating temperature: -5°C to 50°C (23°F to 122°F)
Storage temperature: -40°C to +85°C (-40°F to +185°F)
Fan module:
Operating temperature: -10°C to 70°C (14°F to 158°F)
Storage temperature: -40°C to +75°C (-40°F to +167°F)
HumidityOperating humidity: 5% RH to 85% RH (non-condensing)
Storage humidity: 5% RH to 95% RH (non-condensing)
Humidity change rate: < 20% RH/h
AltitudeCH140 and CH140 V3 compute nodes
At an altitude of 900 m (2952.72 ft), the highest operating temperature is 35°C (95°F).
Other modules
At an altitude of 900 m (2952.72 ft), the highest operating temperature is 40°C (104°F).
When the device is used at an altitude of 900 m to 5000 m (2952.8 ft to 16404.2 ft), the highest operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.24 ft). At an altitude of over 3000 m (9842.5 ft), only Titanium PSUs can be used.
NoiseThe data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7999 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle:
LWAd: 7.2 Bels
LpAm: 53 dBA
Corrosive air pollutantCorrosion rate of the copper test piece < 300 Å/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)
Corrosion rate of the silver test piece < 200 Å/month
Particulate pollutantThe ISO14664-1 Class 8 requirements are met.
It is recommended that a professional company monitor particulate pollutants in the equipment room.
There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.
Heat dissipation per slotComputer node slot:
35°C (95°F)
Half-width slot: 900 W
Full-width slot: 1800 W
40°C (104°F)
Half-width slot: 700 W
Full-width slot: 1400 W
Switch module slot: 280 W
Management module slot: 80 W
Input voltageDC PSU: -48 V DC to -60 V DC
AC PSU: 100 V AC to 130 V AC, 200 V AC to 220 V AC and 220 V AC to 240 V AC, 50 Hz or 60 Hz
Maximum input current3000 W AC PSU: 16 A
2000 W AC PSU: 10 A
2500 W DC PSU: 80 A
Output voltage12.3 V DC
PSU rated powerA chassis houses a maximum of six PSUs. The following information lists the rated power of each type of PSU:
3000 W AC PSU:
1200 W (for 100 V AC to 130 V AC input)
2500 W (for 200 V AC to 220 V AC input)
3000 W (for 220 V AC to 240 V AC input)
2000 W AC PSU:
800 W (for 100 V AC to 130 V AC input)
1800 W (for 200 V AC to 220 V AC input)
2000 W (for 220 V AC to 240 V AC input)
2500 W DC PSU: 2500 W (for -48 V DC to -60 V DC input)

Model:Tecal  E9000

Detail: Huawei Tecal  E9000 Server,configured  with Compute Nodes: CH121 V3,CH140 V3,CH220 V3,CH222 V3,CH226 V3,CH242 V3,CH121 V2,CH140 V2,CH220 V2,CH221 V2,CH222 V2,CH240 V2,CH242 V2

Condition: Brand New Sealed

Availability: IN STOCK

Contact Us