SmartAX MA5621/MA5621A Multi-Service Access Module (MA5621/MA5621A lühidalt) is a passive cooling multi-dwelling unit (MDU) developed by Huawei for smart grid reconstruction.

MA5621 applies to intelligent electricity consumption information collection networks, MA5621 Aapplies to automatic power site information transmission networks and intelligent electricity consumption information collection networks, at the same time, MA5621/MA5621A apply to video monitoring networks.

Sarnased tooted:

MA5622

MA5620

MA5626

MA5612

Ülevaade
Konfiguratsioon 1 : 220 V AC input of MA5621
Konfiguratsioon 2: 12 V/24 V/48 V DC input of MA5621
Konfiguratsioon 3: GPON Upstream Transmission of MA5621A

The MA5621/MA5621A is a box-type device 1 U (1 U = 44.45 mm) high. MA5621 appearances vary according to the power supply mode.

Konfiguratsioon 1: : 220 V AC input of MA5621
MA5621 välimus (220 V AC sisend)
Konfiguratsioon 2: 12 V/24 V/48 V DC input of MA5621
MA5621 välimus (12 V/24 V/48 V DC input)
Konfiguratsioon 3: GPON Upstream Transmission of MA5621A
MA5621A välimus (GPON Upstream Transmission)
Tabel 1 Ports on MA5621/MA5621A
Pordi nimi Siidiekraan Sadamate arv Funktsioon
Mounting ear - 2 Kasutatakse seadme kinnitamiseks.
Vahelduvvoolu toiteport - 1 Ühendab 220 V Vahelduvvoolu toide.
Üleslingi optiline port MA5621: 0, 1

MA5621A: GPON

MA5621: 2

MA5621A: 1

The MA5621 supports three port types: gigabiti võimeline passiivne optiline võrk (GPON) ja gigabitine Ethernet (ANNA).

The MA5621A supports one port type: gigabiti võimeline passiivne optiline võrk (GPON).

  • GPON port:
    • GPON port uses single-mode optical modules and support bidirectional data transmission over one fiber.
    • Toetatud kiudoptiline pistik on SC/PC (UPC).
  • GE optiline port:
    • Kasutab väikest ühendatavat vormitegurit (SFP) optiline moodul.
    • Toetab erinevaid edastuskaugusi, kasutades erinevaid SFP optilisi mooduleid.
    • Toetab ühe- ja mitmerežiimilisi optilisi mooduleid.
Time output port (reserved) TO 1

MÄRGE:

Only MA5621 supports this port.
Reserved by the system, It can not be used.
Jadapordi kasutuselevõtt KONSOOL 1 Local or remote configuration serial port
Hooldusvõrgu port ETH 1

MÄRGE:

Only MA5621 supports this port.
10 Mbit / s või 100 Mbit/s maintenance Ethernet port
Keskkonnaseire sadam ALARM 1

MÄRGE:

Only MA5621 supports this port.
Toetab nelja digitaalset andurit: ukse olek, ülepingekaitse, peamine jaotusraam, ja suitsuandurid.
GE/FE electrical port MA5621: ANNA

MA5621A: FE

4 MA5621: GE/FE auto-adaptive ports.

MA5621A: FE elektriport.

RS485 serial port (vaikimisi)

:

MA5621: RS485/RS232

MA5621A: RS485

2 The MA5621/MA5621A pakub 2 RS485 serial ports. Each of the serial ports can be configured as RS485 compliant as required.
RS232 serial port (vaikimisi) RS485/RS232 2

MÄRGE:

Only MA5621 supports this port.
Each of the serial ports can be configured as an RS232 serial port as required
Grounding point - 1 Ühendab seadme maapinnaga.
DC power port - 1

MÄRGE:

Only MA5621 supports this port.
Ühendab 12 V, 24 V või 48 V alalisvoolu toide.
Näitajad

The MA5621/MA5621A provides a variety of indicators on its panel to help users learn about the running status of the device.

 

MA5621 Näitaja
MA5621A Näitaja
Tabel 1 Indicators on the MA5621/MA5621A
Näitaja Kirjeldus
PWR: toiteallika oleku indikaator Püsiv roheline Seade on sisse lülitatud.
Väljas Seade on välja lülitatud.
RUN/ALM: tööoleku indikaator Punane ja vilkuv 0,25 s sisse ja 0,25 s välja Seade käivitub.
Roheline ja vilgub 1 s sisse ja 1 s välja Seade töötab korralikult.
Püsiv punane Seade on vigane.
LINK: lingi oleku indikaator Püsiv roheline The optical port is receiving downstream optical signals.
Väljas The optical port fails to receive downstream optical signals or an optical fiber is not connected to the device.
AUTH/ACT: Authentication indicator Püsiv roheline The device registers successfully. The AUTH indicator has this state only when the GPON transmits data upstream.
vastavalt kaitselülitite registreeritud olekule
  • The device is registering when the GPON transmits data upstream.
  • Data is being received or transmitted in the case of GE upstream transmission.
    MÄRGE:

    MA5621A does not support GE upstream transmission.
Väljas Optilist kiudu pole seadmega ühendatud.
TX/RX: serial port status indicators Roheline ja vilgub 0,25 s sisse ja 0,25 s välja The serial port is receiving data.
Green indicator off The serial port receives no data.
Yellow and blinking 0.25s on and 0.25s off The serial port is transmitting data.
Yellow indicator off The serial port does not transmit data.
GE/FE autosensing electrical port status indicators Green indicator steady on Ühendus on loodud pordis.
Green indicator off Pordis pole ühendust seadistatud.
Yellow indicator blinking Port edastab või võtab vastu andmeid.
Yellow indicator off No data is transmitted or received on the port.
Rakenduse stsenaariumid

An MA5621/MA5621A applies to automatic power site information transmission networks, intelligent electricity consumption information collection networks, and video monitoring networks.

Applications in automatic power site information transmission and intelligent electricity consumption information collection networks
Application in a video monitoring network
FE: fast Ethernet FTU: feeder terminal unit
ANNA: gigabit Ethernet MSTP: multi-service transmission platform
OLT: optilise liini terminal OSN: optical wwitch node
RTU: remote terminal unit SCADA: supervisory control and data acquisition
SDH: sünkroonne digitaalne hierarhia TTU: transform terminal unit

An MA5621/MA5621A mainly applies to the following networks:

  • Automatic power site information transmission network: The MA5621 works with an optical line terminal (OLT) to provide a transparent channel for automatically transmitting power site information. Through this channel, power distribution sites can communicate with the distribution automation system in real time. The automatic power site information transmission network supports three typical networking modes: ühekohaline, independent upstream transmission over two optical network unit (TEMA-TEMA-IT) passive optical network (MON) sadamad, and dual-homing.
    • Single-homing: Optical splitters with unequal split ratio connect the OLT to MA5621 . An MA5621 uses two PON ports for upstream transmission and works with the PON ports on the active and standby OLTs to form a hand-in-hand protection network. The two PON ports on the MA5621 are of mutual backup. Only one PON port transmits packets over one PON line at a time.
    • Independent upstream transmission over two ONU PON ports: Optical splitters with unequal split ratio connect the OLT to MA5621 . An MA5621 uses two PON ports for upstream transmission and works with two OLTs to form a hand-in-hand protection network. Both the PON lines between the MA5621 and the OLTs are active and can forward packets at the same time. This feature protects generic object oriented substation event (GOOSE) services without using the optical fibers directly connected between the OLTs or a transmission network.
    • Dual-homing: The only difference between dual-homing and independent upstream transmission over two ONU PON ports lies in that the two PON ports on the MA5621 in dual-homing mode are in active and standby mode. Only one PON port transmits packets over one PON line at a time.
      MÄRGE:

      • Ainult MA5621 supports this automatic power site information transmission network.
      • The MA5621 supports automatic switchback after a dual-homing protection switchover.
  • Intelligent electricity consumption information collection network: The MA5621/MA5621A works with an OLT to provide a transparent channel for intelligently collecting electricity consumption information. This function enables the automatic meter reading system (AMR) server to obtain user electricity consumption information in real time.
    1. MA5621/MA5621A is located near to an electricity meter, such as in an outdoor cabinet or electricity consumption information collector in a residential building. They are connected to concentrators through gigabit Ethernet (ANNA) or fast Ethernet (FE) autonegotiation electrical ports.
    2. The concentrators connect to collectors through power cables. The concentrators send the electricity consumption information collected by the collectors to the MA5621/MA5621A, or the concentrators connect to smart meters through RS485 serial ports and send the electricity consumption information to the MA5621/MA5621A.
    3. The MA5621/MA5621A uses PON uplink ports to transmit the received information to the OLT that is installed at a 110 kV or 35 kV substation. The OLT forwards the information to an upper layer device, which then reports the information to the AMR server.
  • Video monitoring network: The MA5621/MA5621A works with an OLT to provide a transparent channel for transmitting video monitoring information so that the monitoring center can monitor the monitored points in real time.
    1. Located at a monitored point, the MA5621/MA5621A connects to a video monitor through a GE or an FE autonegotiation electrical port to receive video monitoring information.
    2. The MA5621/MA5621A uses PON uplink ports to transmit the received information to the OLT at a monitoring center.
    3. The OLT converges and forwards video monitoring information to other monitors at the monitoring center.

     

Toote omadused

See teema kirjeldab selle funktsioone MA5621/MA5621A.

Comprehensive GPON Kaitse (apply to MA5621)

The MA5621 uses the GPON protection solution to provide higher reliability for access devices.

The MA5621 supports the following GPON protection solutions:

  • GPON type B protection: supported by the MA5621 when the MA5621 works with optical line terminal (OLT) V800R009C00 or later versions
  • GPON type C protection: supported by the MA5621 when the MA5621 works with OLT V800R010C00 or later versions

Passive Cooling

The MA5621 supports passive cooling and can work at a temperature of 70°C (85°C within 2 tundi) using the following technologies:

  • High emissivity coating on shells
  • 6 mm heat dissipation fins on the bottom of the box
  • Bright copper coating on large board areas
  • Low thermal resistance coating on power consumption components and modules

Highly Effective Manageability and Maintainability

  • It supports free of onsite software commissioning.
  • Kui MA5621/MA5621A uses PON port for upstream transmission, It supports One-Site Deployment and Plug and Play. MA5621/MA5621A can automatically obtain the configuration data from the NMS and report its online status to the NMS. (The configuration data automatically takes effect.)
  • Remote Batch Upgrade: The MA5621/MA5621A supports automatic batch upgrade, If the upgrading fails, automatic rollback is supported, An upgrade package combining both the device software and the patch file is provided for upgrade.
  • Nullpuudutuse rutiinne hooldus: The MA5621/MA5621A supports accurate fault location and remote troubleshooting, Backing up and uploading configuration data and obtaining accurate operation logs etc.
  • Network Performance Monitoring: The MA5621/MA5621A supports network optimization and user monitoring.

Reliability Design

The hardware design of the MA5621/MA5621A has the following features:

  • Läbib elektrostaatilise lahenduse (ESD) katsetada.
  • Passes the CE certification and meets the safety requirements specified in IEC60950-1, EN60950-1, IEC60825-1/2, and GB4943.
  • Supports the following surge protection capabilities:
    • Common-mode and differential-mode 6 kV for the AC power port.
    • Common-mode 6 kV for FE/GE auto-adaptive ports and common-mode 4 kV for serial ports.
  • Employs an energy-efficient and silence design.
  • Has fewer lines routed across the surface of the board to achieve a proper heat dissipation effect (temperatuuri erinevuse tekitamine, et vältida kondenseerumist).