Huawei FusionServer RH8100 V3
Bränd: Huawei
Mudel: FusionServer RH8100 V3
Detail: Huawei FusionServer RH8100 V3 rack server,4 või 8 Intel Xeon E7-8800 v2/v3 seeria protsessorid, 192 DDR4 DIMM toetab, RAID, 8 kuumalt vahetatavad ventilaatorimoodulid, 4 vahetatavad toiteallikad
Seisund: Täiesti uus suletud
Saadavus: LAOS
- Kirjeldus
- Spetsifikatsioon
- Tellimisteave
- Päring
The RH8100 V3 provides three front I/O modules:
- The front I/O module of model A (FM-A) provides performance-balanced configuration.The FM-A supports a maximum of 12 SAS-kõvakettad, SATA kõvakettad, või SSD-sid, two RAID controller cards, and six standard PCIe slots on PCIe riser cards. The PCIe slots do not support standard cards that need to connect to external cables, such as, NICs, HBAs, IBs. You can install PCIe SSDs and GPUs in the slots.
- The front I/O module of model B (FM-B) provides storage-enhanced configuration.The FM-B supports a maximum of 24 SAS-kõvakettad, SATA kõvakettad, or SSDs and two RAID controller cards. It does not support standard PCIe slots.
- The front I/O module of model C (FM-C) provides low-level configuration.The FM-C supports a maximum of eight SAS HDDs, SATA kõvakettad, or SSDs and two RAID controller cards. It does not support standard PCIe slots.
- The front I/O module of model D (FM-D) supports NVMe PCIe SSDs.The FM-D supports a maximum of eight SAS HDDs, SATA kõvakettad, SSD-d, or NVMe PCIe SSDs and two RAID controller cards, but does not support standard PCIe slots. NVMe PCIe SSDs do not support RAID. If NVMe PCIe SSDs are installed in all disk slots, no RAID controller cards need to be configured on the server.
Üksus | RH8100 V3 Specifications |
---|---|
Ventilaatori moodul | Hajutage serverist soojust, kiirvahetuse tugi, ja lubada ühe ventilaatori rikkeid. Kui üks ventilaator ebaõnnestub, teiste ventilaatorite kiirust reguleeritakse piirkonna järgi, et tagada soojuse hajumine. |
PSU | Four DC or AC PSUs in 2+2 DDR4 RDIMM-id/LRDIMM-id: AC PSU: converts AC power into 12 V DC power for the RH8100 V3. DC PSU: converts input DC power into 12 V DC power for the RH8100 V3. |
HFC | Consists of a TPM, NIC, LAN on motherboard (LOM), and USB flash drive. An HFC provides the following ports: USB-port Management network port Jadaport VGA port Each HFC has a BCM5720 LOM, which is used as a service NIC. Each LOM has ports 0 ja 1. When two LOMs communicate with each other, sadam 0 on one LOM can communicate with only port 0 on the other LOM, and port 1 on one LOM can communicate with only port 1 on the other LOM. If the RH8100 V3 operates in dual-system mode, one service system can obtain information from the other service system using the LOMs. If the RH8100 V3 operates in single-system mode, the LOMs do not work. standard PCIe 2.0 x4 pesa |
NIC | Üks GE NIC kahe või nelja GE-pordiga Üks 10GE NIC kahe 10GE pordiga |
TPM or TCM | Choose a TPM or TCM as required. A TPM complies with the Trusted Computing Group (TCG) standards and protects the platform from viruses or unauthorized operations. A TCM is a hardware module that provides cryptography computation for a trusted computing platform and has protected storage space. |
USB flash drive | Provides a maximum capacity of 8 GB. |
Hot-swappable PCIe card | Hot-swappable PCIe 3.0 x8 and PCIe 3.0 x16 cards on the rear I/O module |
Non-hot-swappable PCIe card | Non-hot-swappable PCIe 3.0 x8 cards on the rear I/O module |
Rear I/O module | Supports four hot-swappable PCIe cards and six non-hot-swappable PCIe cards. |
Mudel: FusionServer RH8100 V3
Detail: Huawei FusionServer RH8100 V3 rack server,4 või 8 Intel Xeon E7-8800 v2/v3 seeria protsessorid, 192 DDR4 DIMM toetab, RAID, 8 kuumalt vahetatavad ventilaatorimoodulid, 4 vahetatavad toiteallikad
Seisund: Täiesti uus suletud
Saadavus: LAOS