Huawei NE40E-X3 with 2*MPUs, 2*DC toide (CR5P03BASD71) Ülevaade
Huawei NetEngine40E NE40E-X3 series universal service router CR5P03BASD71 Basic Configuration includes NE40E-X3 Chassis, Kaks peamist töötlemisseadet D (MPU-d) ja kahe vahelduvvoolu toiteallikaga, ilma tarkvaratasuta ja dokumendita. The Huawei CR5P03BASD71 router has 3 LPU pesa, 2 MPU pesad ja 2 Alalisvoolu toiteallikad, mis suudab pakkuda kuni 1,08 Tbit/s lülitusvõimsust, 540Mpps-i edastamise jõudlus. It’s designed for large-capacity core and edging network to support mission-critical applications such as video, hääl- ja andmeteenused koos tervikliku kasutajahaldus- ja raamatupidamisfunktsiooniga. Põhineb hajutatud riistvara edastamise ja blokeerimata kommutatsioonitehnoloogiatel, NE40E pakub maksimaalselt 480G liinikaarte, et rahuldada suurenenud nõudlust ribalaiuse järele.
NE40E pakub töökindluskaitset erinevatel tasemetel, sealhulgas varustuse tase, võrgu tasandil, ja teenindustase. NE40E võib pakkuda ka mitmetasandilist töökindluslahendust, mis vastab täielikult erinevate teenuste töökindlusnõuetele. NE40E paneb aluse ettevõtte teenustele, mille süsteem on saadaval 99.999%.
Kiired andmed
Joonis 1 näitab Huawei ruuteri välimust – CR5P03BASD71.
Tabel 1 näitab kiirspetsifikaate.
Toote kood | Huawei ruuter – CR5P03BASD71 |
Lülitusvõimsus | 1.08 Tbit / s |
Edastamise tulemuslikkus | 540 Mpps |
MPU pesad | 2 |
SFU teenindusajad | mitte ühtegi |
LPU pesad | 3 |
Teeninduskaartide pesad | Maksimaalne 12 |
Kaal | 42 kg (DC) |
Mõõtmed (L x S x K) | 175 mm x 442 mm x 650 mm (DC 4U) |
The Optical transceiver
Tabel 2 näitab selle jaoks soovitatud elemente Huawei ruuter – CR5P03BASD71.
Mudel | Kirjeldus |
FE-SFP optiline transiiver | |
SFP-FE-SX-MM1310 | SFP,100M / 155M,Mitmerežiimiline moodul(1310nm,2km,LC) |
eSFP-FE-LX-SM1310 | eSFP,100M / 155M,Ühemoodiline moodul(1310nm,15km,LC) |
S-SFP-FE-LH40-SM1310 | eSFP,FE,Ühemoodiline moodul(1310nm,40km,LC) |
GE-SFP optiline transiiver | |
SFP-1000BaseT | SFP,ANNA,Elektriliidese moodul(100m,RJ45) |
eSFP-GE-SX-MM850 | eSFP,ANNA,Mitmerežiimiline moodul(850nm,0.55km,LC) |
SFP-GE-LX-SM1310 | eSFP,ANNA,Ühemoodiline moodul(1310nm,10km,LC) |
S-SFP-GE-LH40-SM1310 | eSFP,ANNA,Ühemoodiline moodul(1310nm,40km,LC) |
S-SFP-GE-LH40-SM1550 | eSFP,ANNA,Ühemoodiline moodul(1550nm,40km,LC) |
Võrdle sarnaste üksustega
Tabel 3 näitab võrdlust between CR5P03BASD71 and CR5P08BASA71.
Mudel | CR5P03BASD71 | CR5P08BASA71 |
Lülitusvõimsus | 1.08 Tbit / s | 7.08 Tbit / s |
Edastamise tulemuslikkus | 540 Mpps | 2,880 Mpps |
MPU pesad | 2 | 2 |
SFU teenindusajad | mitte ühtegi | 1 |
LPU pesad | 3 | 8 |
Teeninduskaartide pesad | Maksimaalne 12 | Maksimaalne 32 |
Mõõtmed (L x S x K) | 175 mm x 442 mm x 650 mm (DC 4U) | 620 mm x 442 mm x 650 mm (14U) |
Spetsifikatsioonid
Üksus | NE40E-X16A | NE40E-X16 | NE40E-X8A | NE40E-X8 | NE40E-X3A | NE40E-X3 | NE40E-M2H |
---|---|---|---|---|---|---|---|
Lülitusvõimsus | 81.92 Tbit / s | 12.58 Tbit / s | 25.16 Tbit / s | 7.08 Tbit / s | 4.19 Tbit / s | 1.08 Tbit / s | 960G |
Edastamise tulemuslikkus | 48,000 Mpps | 5,760 Mpps | 9,600 Mpps | 2,880 Mpps | 900 MPP* | 360 Mpps | 330 Mpps |
Number of Slots | 22 pilud, kaasa arvatud 2 MPU-d (1:1 varukoopia), 4 SFU-d (3+1 varukoopia), ja 16 LPUs | 22 pilud, kaasa arvatud 2 MPU-d (1:1 varukoopia), 4 SFU-d(3+1 varukoopia), ja 16 LPUs | 12 pilud, kaasa arvatud 2 SRUs (1:1 varukoopia), 2 SFU-d (3+1 varukoopia), ja 8 LPUs | 11 pilud, kaasa arvatud 2 SRUs (1:1 varukoopia), 1 SFU-d(2+1 varukoopia), ja 8 LPUs | 5 pilud (jaoks 3 LPUs and 2 MPU-d) | 5 pilud (jaoks 3 LPUs and 2 MPU-d) | 2 pilud |
Mõõtmed (L x S x K) | 442 mm x 650 mm x 1,778 mm (40U) | 442 mm x 650 mm x 1,420 mm (32U) | 442 mm x 650 mm x 934 mm (21U) | 442 mm x 650 mm x 620 mm (14U) | 442 mm x 664 mm x 264 mm (6U) | 442 mm x 650 mm x 175 mm (DC, 4U); 442 mm x 650 mm x 220 mm (AC, 5U) | 442 mm x 220 mm x 89 mm (2U) |
Energiatarve (in full configuration) | 9,040W (480G) | 4,610W (120G) 7,970W (240G) | 4,770W (480G) | 2,340W (120G) 4,100W (240G) | 600W (200G) | 1,070W (AC) 920W (DC) | 537W (AC) 499W (DC) |
Kaal (in full configuration) | 356 kg (480G) | 246 kg (120G) 279 kg (240G) | 186 kg (480G) | 119 kg (120G) 136 kg (240G) | 75 kg (200G) | 42 kg (DC) 52 kg (AC) | 11 kg (DC) 12 kg (AC) |
Interface Types | 100 GE/40 GE 10 GE-LAN/WAN GE/FE OC-192c/STM-64c POS OC-48c/STM-16c POS OC-12c/STM-4c POS OC-3c/STM-1cPOS Channelized OC-3/STM-1 Channelized STM-4 OC-3c/STM-1c ATM OC-12c/STM-4c ATM E3/T3 CE1/CT1 | ||||||
IPv4 | Support for static routing as well as dynamic routing protocols, nagu RIP, OSPF, ON-ON, and BGP-4 Line rate forwarding on all interfaces in complex routing environments, Järgmisel joonisel on näidatud DCDU-de asukohad kappides, mida kasutavad BTS3900As ja DBS3900s, when route flapping occurs | ||||||
IPv6 | Various IPv4-to-IPv6 transition technologies: manual tunnel, automatic tunnel, 6to4 tunnel, GRE tunnel, and ISATAP tunnel IPv4 over IPv6 tunnel and IPv6 Provider Edge (6PE) IPv6 static routes and dynamic routing protocols, such as BGP4+, RIPng, OSPFv3, and IS-ISv6 IPv6 neighbor discovery, PMTU discovery, TCP6, ping IPv6, tracert IPv6, pistikupesa IPv6, static IPv6 DNS, IPv6 DNS server, TFTP IPv6 client, and IPv6 policy-based routing Internet Control Message Protocol Version 6 (ICMPv6), Management Information Base (MIB), User Datagram Protocol Version 6 (UDP6) MIB, TCP6 MIB, and IPv6 MIB L2NAT, NAT444, DS-Lite, and NAT64 | ||||||
MPLS | MPLS TE and MPLS/BGP VPN, in compliance with RFC 2547 Inter-AS VPN Option A/B/C Integration with Internet services Martini and Kompella MPLS L2VPN L2VPN techniques, such as VPLS and VLL IP interworking over heterogeneous media Multicast VPN MPLS-TP, EVPN, Remote LFA | ||||||
Kiht 2 Funktsioonid | IEEE 802.1Q, IEEE802.1ad, IEEE 802.1D, IEEE 802,1w, and IEEE 802.1s VLAN aggregation (super VLAN) Filtering list based on MAC addresses and ports 1483B802.1s | ||||||
Usaldusväärsus | IP/LDP/VPN/TE/VLL FRR Protection mechanisms such as IP/TE auto-rerouting, IGP/BGP/multicast route convergence, VRRP, PR, IP-Trunk load balancing and backup, BFD, MPLS/Ethernet OAM, Y.1731, and routing protocol/port/VLAN damping PW redundancy, E-Trunk, E-APS, and E-STP In-service patching for smooth software upgrade Passive backplane design Redundancy backup for key components, such as route processing modules, SFU-d, and power modules to guard against single points of failure Switching between components that hot-backup each other GR, NSF, NSR, and ISSU Hot swap of all components | ||||||
QoS | Well-designed HQoS and advanced scheduling and congestion avoidance technologies on each LPU Accurate traffic policing and traffic shaping Complex rule definition and fine-grained flow identification MPLS H-QoS, ensuring QoS for MPLS VPN, VLL, and PWE3 services 8CT that combines MPLS TE and the DiffServ model TE-tunnel-oriented QoS | ||||||
OAM | Y.1731, IP FPM, RFC 2544, MPLS OAM, 802.1ag, and 802.3ah, OPS | ||||||
Multisaade | IGMPv1, IGMPv2, and IGMPv3 Multicast routing protocols, including PIM-DM, PIM-SM, PIM-SSM, Multisaadete allika avastamise protokoll (MSDP), and Multiprotocol BGP (MBGP) Static multicast Multisaadete CAC Interoperability between multicast protocols Processing of multicast policies based on multicast routing protocols and multicast forwarding Multicast QoS and multicast replication for IPoE access users Two-level multicast replication on the SFUs and LPUs to optimize the multicast effect | ||||||
Turvalisus | ACL-based packet filtering URPF GTSM DHCP nuhkimine ARP attack defense and DoS attack defense MAC address limit and MAC-IP binding Turvaline Shell (SSH) and SSH version 2 (SSH v2) BGP-Flowspec RIPv2, OSPF, ON-ON, and BGP MD5, SHA256, Keychain | ||||||
Value-added Services | IPsec tunnel Distributed GRE tunnel Distributed NetStream High-precision NAT: CGN | ||||||
Environmental Requirements | Pikaajaline töötemperatuur: 0° C kuni 45 ° C Lühiajaline töötemperatuur: -5°C kuni 55 °C Long-term operating humidity: 5% RH kuni 85% RH Short-term operating humidity: 0% RH kuni 100% RH Töökõrgus: 3,000 meetrit |
Tellimisteave
Bränd: Huawei
Mudel: CR5P03BASD71
Detail: 02354367 Huawei NetEngine NE40E-X3 seeria ruuteri CR5P03BASD71 NE40E-X3 põhikonfiguratsioon (Kaasa šassii NE40E-X3, 2 MPU-d, 2 DC toide, ilma tarkvaratasuta ja dokumendita)
Seisund: Täiesti uus suletud
Saadavus: LAOS