Huawei FusionServer RH8100 V3

Huawei FusionServer RH8100 V3

Mærke: Huawei

Model: FusionServer RH8100 V3

Detalje: Huawei FusionServer RH8100 V3 Rackserver,4 eller 8 Intel Xeon E7-8800 v2 / v3-serie processorer, 192 DDR4 DIMM'er understøtter, RAID, 8 hot-swappable ventilatormoduler, 4 hot-swappable strømforsyninger

Tilstand: Helt ny forseglet

Tilgængelighed: PÅ LAGER

  • Beskrivelse
  • Specifikation
  • Ordreinformation
  • Forespørgsel

The RH8100 V3 provides three front I/O modules:

  • The front I/O module of model A (FM-A) provides performance-balanced configuration.The FM-A supports a maximum of 12 SAS HDD'er, SATA-harddiske, eller SSD'er, two RAID controller cards, and six standard PCIe slots on PCIe riser cards. The PCIe slots do not support standard cards that need to connect to external cables, såsom, NICs, HBAs, IBs. You can install PCIe SSDs and GPUs in the slots.
  • The front I/O module of model B (FM-B) provides storage-enhanced configuration.The FM-B supports a maximum of 24 SAS HDD'er, SATA-harddiske, or SSDs and two RAID controller cards. It does not support standard PCIe slots.
  • The front I/O module of model C (FM-C) provides low-level configuration.The FM-C supports a maximum of eight SAS HDDs, SATA-harddiske, or SSDs and two RAID controller cards. It does not support standard PCIe slots.
  • The front I/O module of model D (FM-D) supports NVMe PCIe SSDs.The FM-D supports a maximum of eight SAS HDDs, SATA-harddiske, SSD'er, or NVMe PCIe SSDs and two RAID controller cards, but does not support standard PCIe slots. NVMe PCIe SSDs do not support RAID. If NVMe PCIe SSDs are installed in all disk slots, no RAID controller cards need to be configured on the server.

RH8100-V3

VareRH8100 V3 Specifications
Ventilator modulAfled varmen fra serveren, understøtte hot swap, og tillade en-fan-fejl. Hvis en ventilator fejler, de andre ventilators hastighed justeres efter område for at sikre varmeafledning.
PSUFour DC or AC PSUs in 2+2 redundans-tilstand:
AC PSU: converts AC power into 12 V DC power for the RH8100 V3.
DC PSU: converts input DC power into 12 V DC power for the RH8100 V3.
HFCConsists of a TPM, NIC, LAN on motherboard (LOM), and USB flash drive.
An HFC provides the following ports:
USB-port
Management network port
Serial port
VGA port
Each HFC has a BCM5720 LOM, which is used as a service NIC.
Each LOM has ports 0 og 1. When two LOMs communicate with each other, Havn 0 on one LOM can communicate with only port 0 on the other LOM, and port 1 on one LOM can communicate with only port 1 on the other LOM.
If the RH8100 V3 operates in dual-system mode, one service system can obtain information from the other service system using the LOMs.
If the RH8100 V3 operates in single-system mode, the LOMs do not work. standard PCIe 2.0 x4 slot
NICEn GE NIC med to eller fire GE-porte
Et 10GE NIC med to 10GE-porte
TPM or TCMChoose a TPM or TCM as required.
A TPM complies with the Trusted Computing Group (TCG) standards and protects the platform from viruses or unauthorized operations.
A TCM is a hardware module that provides cryptography computation for a trusted computing platform and has protected storage space.
USB flash driveProvides a maximum capacity of 8 GB.
Hot-swappable PCIe cardHot-swappable PCIe 3.0 x8 and PCIe 3.0 x16 cards on the rear I/O module
Non-hot-swappable PCIe cardNon-hot-swappable PCIe 3.0 x8 cards on the rear I/O module
Rear I/O moduleSupports four hot-swappable PCIe cards and six non-hot-swappable PCIe cards.

Model: FusionServer RH8100 V3

Detalje: Huawei FusionServer RH8100 V3 Rackserver,4 eller 8 Intel Xeon E7-8800 v2 / v3-serie processorer, 192 DDR4 DIMM'er understøtter, RAID, 8 hot-swappable ventilatormoduler, 4 hot-swappable strømforsyninger

Tilstand: Helt ny forseglet

Tilgængelighed: PÅ LAGER

Kontakt os