Huawei BWS 1600G

Mærke: Huawei

Model: OptiX BWS 1600G

Detalje:OptiX BWS 1600G transmissionskapacitet af type I-systemet kan opgraderes op til 1600 Gbit / s ved at tilføje moduler til 400 Gbit / s kapacitet. I et modul af 400 Gbit.

Tilstand: Helt ny forseglet

Tilgængelighed: PÅ LAGER

  • Beskrivelse
  • Specifikation
  • Ordreinformation
  • Forespørgsel

An OptiX BWS 1600G system adopts an ETSI300-119-3 standard cabinet. Derfor, the system is rational in cabinet structure and graceful in appearance.

The main frame of the cabinet is a rack with a door fixed at the front, a rear door with air vents fixed at the back and movable side doors at both sides. The power box is mounted at the top. The DCM frame and the HUB frame are installed at the bottom of the cabinet. The subracks are installed in the middle of the cabinet.

The cabinet features the following:

  • The cabinet has a front door. Besides, each subrack is equipped with a door that provides a good shelter for the subrack.
  • The cabinet leaves much space for routing and managing optical fibers and cables.
  • Two movable side doors are installed at both sides of the cabinet. Each side door can move in or move out along a slide rail on the top and the bottom of the cabinet.
  • Air vents are provided at the front door of the subrack, the rear door and upper enclosure frame of the cabinet to ensure heat dissipation.

 

Technical specifications of the cabinet
Vare 2-m High Cabinet 2.2-m High Cabinet 2.6-m High Cabinet
Dimensioner (Height x Width x Depth) 2000 mm x 600 mm x 300 mm (78.8 i. x 23.6 i. x 11.8 i.) 2200 mm x 600 mm x 300 mm (86.6 i. x 23.6 i. x 11.8 i.) 2600 mm x 600 mm x 300 mm (102.3 i. x 23.6 i. x 11.8 i.)
Vægt (Includes the empty cabinet and power box.) 56 kg (123 lb.) 60 kg (132 lb.) 67 kg (148 lb.)
Maksimalt strømforbrug 1300 W 2000 W 2000 W
Nominal working voltage -48 V DC/-60 V DC -48 V DC/-60 V DC -48 V DC/-60 V DC
Arbejdsspændingsområde -38.4 V til -57.6 V DC/-48 V to -72 V DC -38.4 V til -57.6 V DC/-48 V to -72 V DC -38.4 V til -57.6 V DC/-48 V to -72 V DC
Description of the interfaces in the interface area enhanced subrack
Interface Stik Fungere
ETHERNET1 -en RJ-45 Serves as the Telecom management network (TMN) interface and local NE management interface.

It connects to the ETHERNET2 interface on another subrack through cross-over network cables, to achieve the inter-subrack communication concatenation.

ETHERNET2 -en RJ-45
  • Serves as the communication interface with the ROP board in the remote optical pumping amplifier (ROPA) system.
  • When the WMU is configured for centralized wavelength monitoring, ETHERNET2 can be used as a backup network interface for inter-subrack communication.
  • It connects to the ETHERNET1 interface on another subrack through cross-over network cables, to achieve the inter-subrack communication concatenation.
PHONE1/PHONE2/PHONE3 RJ-45 Serves as the orderwire phone interface that uses the optical supervisory channel (OSC) and electrical supervisory channel (ESC). Giver eksterne alarmporte med tre indgange og én udgange 64 kbit/s orderwire voice channel for direct orderwire communication between terminals.
CLOCK IN1–IN2 SMB Serve as two clock input 75-ohm interfaces to access 2048 kbit/s or 2048 kHz clock signals from the equipment at the local station.
OUT1–OUT4 SMB Serve as four clock output 75-ohm interfaces to output 2048 kbit/s or 2048 kHz clock signals to the equipment at the local station.
OCU CLKIN SMB Serve as two external clock source interfaces for the board in the system of the early version.
F&f DB9 Possesses all the features of RS-232 interface. Serves only as an interface for software internal testing.
Serial 1 DB9 Uses the F2 byte of the supervisory channel and possesses the features of both RS-232 and RS-422 interfaces. The maximum rate is 19.2 kbit / s.
Serial2 DB9 Uses the F3 byte of the supervisory channel and possesses the features of both RS-232 and RS-422 interfaces. The maximum rate is 19.2 kbit / s.
ALM DB9 Serves for subrack alarm output. The ALM communicates with the PMU board located in the power box. The ALM is connected with the subrack communication interface (SERIAL) on the power box panel.
F1 DB9 Serves as a 64 kbit/s co-directional data interface.
OAM -en DB9 Serves as a local NE management interface. Operation, administration and maintenance interface.
STRØM DB3 Serves as a subrack power supply interface.
-en: Authentication is required before this port is connected. For at være specifik, you must log in to the NE using the NE administrator account for authentication.

Model: OptiX BWS 1600G

Detalje:OptiX BWS 1600G transmissionskapacitet af type I-systemet kan opgraderes op til 1600 Gbit / s ved at tilføje moduler til 400 Gbit / s kapacitet. I et modul af 400 Gbit .

Tilstand: Helt ny forseglet

Tilgængelighed: PÅ LAGER

Kontakt os