Huawei OceanStor SNS5604
Brand: Huawei
Model: OceanStor SNS5604
Detail:OceanStor SNS5604 6.1 Tbit/s Bandwidth per chassis (192 ports x 32 Gbit/s) data rate + 2.048 Tbit/s UltraScale ICL bandwidth (16 x 128 Gbit/s)
Condition: Brand New Sealed
Availability: IN STOCK
- Description
- Specification
- Ordering information
- Inquiry
Huawei OceanStor SNS5604 Directors are proven and dedicated network infrastructure products oriented to data centers’ mission-critical business.
Using Gen 6 Fiber Channel, Fabric Vision technology, and IO Insight, the directors deliver unmatched 32 Gbit/s performance, seamless scalability, and high reliability.
- Enhance operational stability, maximize application performance, and increase business agility with enterprise-class Gen 6 directors which accelerate application response time by up to 71%
- Provide “pay-as-you-grow” flexibility and Ports-on-Demand (PoD) capabilities for port expansion with a port rate up to 32 Gbit/s
- Simplify end-to-end management of large-scale environments by automating monitoring and diagnostics, for simpler, flatter, low-latency fabrics
Model | SNS5604 | SNS5608 |
Number of Ports | Up to 192 x 32 Gbit/s ports or a 256-port equivalent with 16 UltraScale ICL ports | Up to 384 x 32 Gbit/s ports or a 512-port equivalent with 128 Gbit/s (4 x 32 Gbit/s) UltraScale ICL ports (32 Gbit/s x 4 QSFP ports) |
Port Types | FC32-48 port blade: F Port, E Port, EX Port, M Port, SIM, and D Port
SX6 Extension Blade: F Port, E Port, and EX Port on FC, and VE Port on GbE |
|
Fiber Channel Blades | FC32-48 port blade provides 48 ports of 32 Gbit/s Gen 6 Fiber Channel | |
Extension Blades | SX6 Extension Blade provides Fiber Channel extension (16 x 32 Gbit/s Fiber Channel ports) and IP extension over IP networks (16 x 1/10 GbE and 2 x 40 GbE ports) | |
Scalability | Full-fabric architecture of 239 switches | |
Chassis Bandwidth | 6.1 Tbit/s per chassis (192 ports x 32 Gbit/s) data rate + 2.048 Tbit/s UltraScale ICL bandwidth (16 x 128 Gbit/s) | 12.2 Tbit/s per chassis (384 ports x 32 Gbit/s) data rate + 4.096 Tbit/s UltraScale ICL bandwidth (32 x 128 Gbit/s) |
Slot Bandwidth | 1,536 Gbit/s (line rate) | |
Switch Latency | FC32-48 blade at Gen 6 32 Gbit/s speeds: < 900 ns (including FEC); any-port-to-any-port local switching and 2.7 μs blade to blade at 32 Gbit/s, cut-through routing
SX6 blade, Fiber Channel to Fiber Channel: < 900 ns (including FEC) and 2.7 μs any-port-to-any-port at 32 Gbit/s, cut-through routing |
|
Maximum Frame Size | 2,112-byte payload | |
Frame Buffers | 15,360 per switching ASIC |
OcesnStor SNS5604 | OcesnStor SNS5608 | |
---|---|---|
Chassis | Single chassis: • Up to 192 32 Gbps(E, F, D, M, SIM, AE, and EX) Fibre Channel ports using 48-port 32 Gbps Fibre Channel blades. • Up to 256-port equivalent with with 16 128 Gbps UltraScale ICL ports (4x32 Gbps QSFP ports). | Single chassis: • Up to 384 32 Gbps(E, F, D, M, SIM, AE, and EX) Fibre Channel ports using 48-port 32 Gbps Fibre Channel blades. • Up to 512-port equivalent with with 32 128 Gbps UltraScale ICL ports (4x32 Gbps QSFP ports). |
Control processor | • Redundant (active/standby) control processor modules | • Redundant (active/standby) control processor modules |
System processors | • FreeScale P4080 (8 core), 1.5 GHz | • FreeScale P4080 (8 core), 1.5 GHz |
Scalability | • Full-fabric architecture of 239 switches | • Full-fabric architecture of 239 switches |
Certified maximum | • 6000 active devices per switch; • 56 switches, 19 hops in Fabric OS fabrics; • larger fabrics certified as required | • 6000 active devices per switch; • 56 switches, 19 hops in Fabric OS fabrics; • larger fabrics certified as required |
Fibre Channel blades | • FC32-48 port blade provides 48 ports of 32 Gbps Gen 6 Fibre Channel | • FC32-48 port blade provides 48 ports of 32 Gbps Gen 6 Fibre Channel |
Extension blades | • SX6 Extension Blade provides Fibre Channel extension (16×32 Gbps Fibre Channel ports) and IP extension over IP networks (16×1/10 GbE and 2×40 GbE ports) | • SX6 Extension Blade provides Fibre Channel extension (16×32 Gbps Fibre Channel ports) and IP extension over IP networks (16×1/10 GbE and 2×40 GbE ports) |
Performance | • line speed, full duplex(4, 8, 16, and 32 Gbps) • Autosensing of 4, 8, 16, and 32 Gbps port speeds depending on SFPs used; • 10 Gbps port speeds with dedicated SFPs. | • line speed, full duplex(4, 8, 16, and 32 Gbps) • Autosensing of 4, 8, 16, and 32 Gbps port speeds depending on SFPs used; • 10 Gbps port speeds with dedicated SFPs. |
ISL Trunking | • Frame-based trunking with up to eight 32 Gbps ports per ISL trunk; • up to 256 Gbps per ISL trunk; • Exchange-based load balancing across ISLs with DPS included in FOS. | • Frame-based trunking with up to eight 32 Gbps ports per ISL trunk; • up to 256 Gbps per ISL trunk; • Exchange-based load balancing across ISLs with DPS included in FOS. |
UltraScale ICL trunking | • Chassis-to-chassis linkage through connectors on the Core Routing (CR) blade • Can configure the following maximum QSFPs per trunk depending on blade type, connecting: - Up to four 4×32 Gbps QSFP ports in a trunk group to form a 512 Gbps trunk between two CR32-4 blades. For trunks containing four or fewer QSFP ports, ports in a trunk must be located in the same port group on each blade. - Up to four 4×32 Gbps QSFP ports in a trunk group to form a 512 Gbps trunk between a Brocade CR32-4 and CR32-8 blade. For trunks containing four or fewer QSFP ports, ports in a trunk must be located in the same port group on each blade. • A minimum of two QSFP connections are required for a trunk, and up to four 4×16 Gbps QSFP trunks between pairs of CR32-4 and CR16-4. | • Chassis-to-chassis linkage through connectors on the Core Routing (CR) blade • Can configure the following maximum QSFPs per trunk depending on blade type, connecting: - Up to four 4×32 Gbps QSFP ports in a trunk group to form a 512 Gbps trunk between two CR32-4 blades. For trunks containing four or fewer QSFP ports, ports in a trunk must be located in the same port group on each blade. - Up to four 4×32 Gbps QSFP ports in a trunk group to form a 512 Gbps trunk between a Brocade CR32-4 and CR32-8 blade. For trunks containing four or fewer QSFP ports, ports in a trunk must be located in the same port group on each blade. • A minimum of two QSFP connections are required for a trunk, and up to four 4×16 Gbps QSFP trunks between pairs of CR32-8 and CR16-8. |
Multichassis with UltraScale ICL ports | • Up to 4,608 non-blocking 32 Gbps Fibre Channel ports; • UtraScale ICL ports (16 per 4-slot chassis, optical QSFP) connect up to nine chassis in a full mesh topology or up to 12 chassis in a core-edge topology. | • Up to 4,608 non-blocking 32 Gbps Fibre Channel ports; • UtraScale ICL ports (32 per 8-slot chassis, optical QSFP) connect up to nine chassis in a full mesh topology or up to 12 chassis in a core-edge topology. |
UltraScale ICL bandwidth | • 2.048 Tbps; 16 UltraScale ICL ports provide the equivalent of 64 32 Gbps ports. Each UltraScale ICL port provides 128 Gbps bandwidth over a QSFP (32 Gbps×4) link. • Frame-based trunking is enabled between four UltraScale ICLs. DPS distributes exchanges across all frame trunks. | • 4.096 Tbps; 32 UltraScale ICL ports provide the equivalent of 128 32 Gbps ports. Each UltraScale ICL port provides 128 Gbps bandwidth over a QSFP (32 Gbps×4) link. • Frame-based trunking is enabled between four UltraScale ICLs. DPS distributes exchanges across all frame trunks. |
Chassis bandwidth | • 6.1 Tbps per chassis (192 ports×32 Gbps) data rate + 2.048 Tbps UltraScale ICL bandwidth (16×128 Gbps) | • 12.2 Tbps per chassis (384 ports×32 Gbps) data rate + 4.096 Tbps UltraScale ICL bandwidth (32×128 Gbps) |
Slot bandwidth | • 1,536 Gbps (line rate) | • 1,536 Gbps (line rate) |
Local switching bandwidth | • 1.5 Tbps for Brocade FC32-48: 48 ports × 32 Gbps (data rate) | • 1.5 Tbps for Brocade FC32-48: 48 ports × 32 Gbps (data rate) |
Switch latency | • FC32-48 blade: - Locally switched port latency <900 ns (including FEC) - Blade-to-blade latency is 2.7 μs • SX6 blade: - Fibre Channel to Fibre Channel: <900ns (including FEC) - Any-port-to-any-port latency is 2.7 μs | • FC32-48 blade: - Locally switched port latency <900 ns (including FEC) - Blade-to-blade latency is 2.7 μs • SX6 blade: - Fibre Channel to Fibre Channel: <900ns (including FEC) - Any-port-to-any-port latency is 2.7 μs |
Maximum frame size | • 2112 byte payload | • 2112 byte payload |
Frame buffers | • 15,000 per switching ASIC | • 15,000 per switching ASIC |
Classes of service | • Class 2, Class 3, Class F (inter-switch frames) | • Class 2, Class 3, Class F (inter-switch frames) |
Fibre Channel port types | • FC32-48 port blade: F_Port, E_Port, EX_Port, M_Port, SIM, and D_Port; • SX6 Extension Blade: F_Port, E_Port, and EX_Port on FC, and VE_Port on GbE • NOTE: Self-discovery is based on switch type (U_Port) with an optional port-type control | • FC32-48 port blade: F_Port, E_Port, EX_Port, M_Port, SIM, and D_Port; • SX6 Extension Blade: F_Port, E_Port, and EX_Port on FC, and VE_Port on GbE • NOTE: Self-discovery is based on switch type (U_Port) with an optional port-type control |
Data traffic types | • Fabric switches supporting unicast, multicast (255 groups), and broadcast | • Fabric switches supporting unicast, multicast (255 groups), and broadcast |
Media types | • FC32-48 port blade: Supports hot-pluggable Brocade Fibre Channel SFP+ at 32 Gbps SWL/LWL and SFP+ at 16 Gbps SWL/LWL/ELWL, 10 Gbps SWL/LWL SFP • SX6 Extension Blade: Supports hot-pluggable Brocade Fibre Channel SFP+ at 32 Gbps SWL/LWL; SFP+ at 16 Gbps SWL/LWL/ELWL; SFP at 10 Gbps FC SWL/LWL and Ethernet SFP+ at 1 GbE copper, 1 GbE 1000BASE-SX/LX/CWDM, SFP+ at 10 GbE SR/LR; SFP+ at 10 GbE tunable DWDM 80 km, and QSFP at 40 GbE SR4/LR4/ER4 • Core Routing (CR) blades,CR32-4: Support hot-pluggable Brocade Fibre Channel QSFP at 4×32 Gbps SWL, 4×16 Gbps SWL and 4×16 Gbps 2 km QSFP for ICL connections | • FC32-48 port blade: Supports hot-pluggable Brocade Fibre Channel SFP+ at 32 Gbps SWL/LWL and SFP+ at 16 Gbps SWL/LWL/ELWL, 10 Gbps SWL/LWL SFP • SX6 Extension Blade: Supports hot-pluggable Brocade Fibre Channel SFP+ at 32 Gbps SWL/LWL; SFP+ at 16 Gbps SWL/LWL/ELWL; SFP at 10 Gbps FC SWL/LWL and Ethernet SFP+ at 1 GbE copper, 1 GbE 1000BASE-SX/LX/CWDM, SFP+ at 10 GbE SR/LR; SFP+ at 10 GbE tunable DWDM 80 km, and QSFP at 40 GbE SR4/LR4/ER4 • Core Routing (CR) blades, CR32-8: Support hot-pluggable Brocade Fibre Channel QSFP at 4×32 Gbps SWL, 4×16 Gbps SWL and 4×16 Gbps 2 km QSFP for ICL connections |
USB | • One USB port per control processor for firmware download, support save, and configuration upload or download | • One USB port per control processor for firmware download, support save, and configuration upload or download |
Fabric services | • Adaptive Networking (Traffic Isolation, QoS); BB credit recovery; Brocade Advanced Zoning (default zoning, port/WWN zoning, peer zoning, target-driven zoning, broadcast zoning); Dynamic Path Selection (DPS); Extended Fabrics; FDMI; FICON CUP; Flow Vision; Frame Redirection; FSPF; IPFC; ISL Trunking; Management Server; Monitoring and Alerting Policy Suite (MAPS); N_Port Trunking; NPIV; NTP v3; Port Fencing; Registered State Change Notification (RSCN); Reliable Commit Service (RCS); Simple Name Server | • Adaptive Networking (Traffic Isolation, QoS); BB credit recovery; Brocade Advanced Zoning (default zoning, port/WWN zoning, peer zoning, target-driven zoning, broadcast zoning); Dynamic Path Selection (DPS); Extended Fabrics; FDMI; FICON CUP; Flow Vision; Frame Redirection; FSPF; IPFC; ISL Trunking; Management Server; Monitoring and Alerting Policy Suite (MAPS); N_Port Trunking; NPIV; NTP v3; Port Fencing; Registered State Change Notification (RSCN); Reliable Commit Service (RCS); Simple Name Server |
Extension | • Supports DWDM, CWDM, and FC-SONET devices; Fibre Channel, in-flight compression (Brocade LZO) and encryption (AES-GCM-256); BB credit recovery; FCIP, IP Extension, Adaptive Rate Limiting (ARL), data compression, Fast Write, read/write Tape Pipelining, QoS | • Supports DWDM, CWDM, and FC-SONET devices; Fibre Channel, in-flight compression (Brocade LZO) and encryption (AES-GCM-256); BB credit recovery; FCIP, IP Extension, Adaptive Rate Limiting (ARL), data compression, Fast Write, read/write Tape Pipelining, QoS |
FICON | • FFICON cascading; support for lossless DLS; FICON CUP; Advanced Accelerator for FICON (IBM z/OS Global Mirror and read/write Tape Pipelining) | • FFICON cascading; support for lossless DLS; FICON CUP; Advanced Accelerator for FICON (IBM z/OS Global Mirror and read/write Tape Pipelining) |
Fibre Channel ports | • Up to 192 32-Gbps ports, universal (F_Port, E_Port, EX_Port, M_Port, D_Port, SIM Port, FICON) | • Up to 384 32-Gbps ports, universal (F_Port, E_Port, EX_Port, M_Port, D_Port, SIM Port, FICON) |
Classes of service | • Class 2, Class 3, Class F (inter-switch frames) | • Class 2, Class 3, Class F (inter-switch frames) |
ANSI Fibre Channel protocol | • FC-PH (Fibre Channel Physical and Signaling Interface standard) | • FC-PH (Fibre Channel Physical and Signaling Interface standard) |
Fabric initialization | • Complies with FC-SW 5.0 | • Complies with FC-SW 5.0 |
IP Extension (IP over Fibre Channel) | • Complies with FC-IP 2.3 of the FCA profile | • Complies with FC-IP 2.3 of the FCA profile |
Port to port latency | • Local switching: 900 ns • Blade to blade: 2.7 μs | • Local switching: 900 ns • Blade to blade: 2.7 μs |
Switching capacity | • An aggregate switching capacity of 13.5 billion frames per second (for Class 2, Class 3, and Class F frames for a 384-port chassis) | • An aggregate switching capacity of 13.5 billion frames per second (for Class 2, Class 3, and Class F frames for a 384-port chassis) |
Architecture | • Non-blocking shared memory; • passive backplane; • redundant active/passive control processor; • redundant active/active core switching blades; • redundant WWN card | • Non-blocking shared memory; • passive backplane; • redundant active/passive control processor; • redundant active/active core switching blades; • redundant WWN card |
Chassis power | • Two power supplies required for AC Low Line (100 VAC to 120 VAC). • One power supply required for AC High Line (200 VAC to 240 VAC). • The device ships with two power supplies. One provides system power, but both must be installed to provide power efficiency and 1+1 redundancy. | • Four power supplies required for AC Low Line (100 VAC to 120 VAC). • Two power supplies required for AC High Line (200 VAC to 240 VAC). • Device ships with three PSUs or empty (3 for 2+1 redundancy). Two provide system power, but four must be installed to provide power efficiency and 2+2 redundancy. |
Cooling | • Requires two fan tray assemblies. A failure condition is one failed fan from any fan tray. • Each assembly contains two fans for a total of four. The system requires three of four functioning fans for operation in the SNS5604. One fan assembly can be hot-swapped and should be replaced immediately in the event of a failure. | • Requires three fan tray assemblies. A failure condition is one failed fan from any fan tray. • Each assembly contains two fans for a total of six. The system requires five of six functioning fans for operation in the SNS5608. One fan tray assembly can be hot-swapped and should be replaced immediately in the event of a failure. |
Airflow | • Non-port-side intake to port-side exhaust or port-side intake to non-port-side exhaust options are available. | • Non-port-side intake to port-side exhaust or port-side intake to non-port-side exhaust options are available. |
Solution availability | • Designed to provide 99.999 percent uptime capabilities; • hot-pluggable redundant power supplies, fans, WWN cards, processors, core switching, port blades, and optics; • online diagnostics; • non-disruptive firmware download and activation | • Designed to provide 99.999 percent uptime capabilities; • hot-pluggable redundant power supplies, fans, WWN cards, processors, core switching, port blades, and optics; • online diagnostics; • non-disruptive firmware download and activation |
Management | • HTTP, SNMP v1/v3 (FE MIB, FC Management MIB), SSH; Auditing, Syslog; Advanced Web Tools, Brocade Network Advisor SAN Enterprise or Brocade Network Advisor SAN Professional Plus; Command Line Interface (CLI); SMI-S compliant; RESTful API; trial licenses for add-on capabilities | • HTTP, SNMP v1/v3 (FE MIB, FC Management MIB), SSH; Auditing, Syslog; Advanced Web Tools, Brocade Network Advisor SAN Enterprise or Brocade Network Advisor SAN Professional Plus; Command Line Interface (CLI); SMI-S compliant; RESTful API; trial licenses for add-on capabilities |
Security | • DH-CHAP (between switches and end devices), FCAP switch authentication, FIPS 140-2 L2-compliant, HTTPS, IPsec, IP filtering, LDAP with IPv6, OpenLDAP, Port Binding, RADIUS, user-defined Role-Based Access Control (RBAC), Secure Copy (SCP), Secure RPC, SFTP, SSH v2, SSL, Switch Binding, TACACS+, Trusted Switch | • DH-CHAP (between switches and end devices), FCAP switch authentication, FIPS 140-2 L2-compliant, HTTPS, IPsec, IP filtering, LDAP with IPv6, OpenLDAP, Port Binding, RADIUS, user-defined Role-Based Access Control (RBAC), Secure Copy (SCP), Secure RPC, SFTP, SSH v2, SSL, Switch Binding, TACACS+, Trusted Switch |
Management access | • 10/100/1000 Ethernet (RJ-45) per control processor, in-band over Fibre Channel; serial port (RJ-45) and one USB per control processor module; DHCP/DHCPv6; call-home integration enabled through Brocade Network Advisor | • 10/100/1000 Ethernet (RJ-45) per control processor, in-band over Fibre Channel; serial port (RJ-45) and one USB per control processor module; DHCP/DHCPv6; call-home integration enabled through Brocade Network Advisor |
Diagnostics | • IO Insight for IO monitoring; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; built-in flow generator; POST and embedded online/offline diagnostics, including environmental monitoring, FCping and Pathinfo (FC traceroute), flow mirroring, frame viewer, non-disruptive daemon restart, optics health monitoring, power monitoring, RAStrace logging, and Rolling Reboot Detection (RRD) | • IO Insight for IO monitoring; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; built-in flow generator; POST and embedded online/offline diagnostics, including environmental monitoring, FCping and Pathinfo (FC traceroute), flow mirroring, frame viewer, non-disruptive daemon restart, optics health monitoring, power monitoring, RAStrace logging, and Rolling Reboot Detection (RRD) |
Temperature | • Operating: 0°C to 40°C (32°F to 104°F) • Non-operating: –25°C to 70°C (–13°F to 158°F) | • Operating: 0°C to 40°C (32°F to 104°F) • Non-operating: –25°C to 70°C (–13°F to 158°F) |
Humidity | • Operating humidity: 5% to 93% RH non-condensing at 40°C (104°F) with a maximum gradient of 10% per hour • Non-operating humidity: 10% to 93% RH non-condensing at 70°C (158°F) | • Operating humidity: 5% to 93% RH non-condensing at 40°C (104°F) with a maximum gradient of 10% per hour • Non-operating humidity: 10% to 93% RH non-condensing at 70°C (158°F) |
Altitude | • Up to 3,000 meters (9,842 feet) | • Up to 3,000 meters (9,842 feet) |
Shock | • Operating: 10 g, 11 ms, half sine wave • Non-operating: 20 g, 11 ms, half sine wave | • Operating: 10 g, 11 ms, half sine wave • Non-operating: 20 g, 11 ms, half sine wave |
Heat dissipation | • 192-port configuration: Typical: 4,696 BTU/hr; Max: 8,139 BTU/hr • Power consumed: Typical: 1,376 W; Max: 2,385 W Note: Input power is at 200 VAC with full PSU redundancy. | • 384-port configuration: Typical: 8,836 BTU/hr; Max: 14,485 BTU/hr • Power consumed: Typical: 2,589 W; Max: 4,244 W Note: Input power is at 200 VAC with full PSU redundancy. |
Operating noise | • 64.2 dB | • 68.2 dB |
Vibration | • Operating: 5 Hz to 10 Hz @ +5 db/Oct; 10 Hz to 200 Hz @ 0.0005 Grms; 200 Hz to 500 Hz @ –5 db/Oct; scale 0.05 Grms • Non-operating: 3 Hz to 10 Hz @ +5 db/Oct; 10 Hz to 200 Hz @ 0.0065 Grms; 200 Hz to 500 Hz @ –5db/Oct; scale 1.12 Grms | • Operating: 5 Hz to 10 Hz @ +5 db/Oct; 10 Hz to 200 Hz @ 0.0005 Grms; 200 Hz to 500 Hz @ –5 db/Oct; scale 0.05 Grms • Non-operating: 3 Hz to 10 Hz @ +5 db/Oct; 10 Hz to 200 Hz @ 0.0065 Grms; 200 Hz to 500 Hz @ –5db/Oct; scale 1.12 Grms |
Availability | • 99.9999% at 1 year | • 99.9999% at 1 year |
MTBF (hours) | • 190,875 | • 127,718 |
MTTR (hours) | • 1.0 | • 1.0 |
Supported power range | • Input voltage Standard AC input: Range: 85 VAC to 264 VAC Auto-volt Nominal: 100 VAC to 240 VAC • Power 85 to 132 VAC: 1,450 W 180 to 264 VAC: 2,870 W | • Input voltage Standard AC input: Range: 85 VAC to 264 VAC Auto-volt Nominal: 100 VAC to 240 VAC • Power 85 to 132 VAC: 1,450 W 180 to 264 VAC: 2,870 W |
In-rush current | • 35 Amps maximum, peak | • 35 Amps maximum, peak |
Frequency | • 50 Hz to 60 Hz (Nominal: 50 Hz to 60 Hz) | • 50 Hz to 60 Hz (Nominal: 50 Hz to 60 Hz) |
Enclosure | • 8U rack-mountable chassis; 27 in. to 31 in. rail, 18 in. to 24 in. rail, and airflow diversion rack mount kits for the four-post rack; mid-mount kit for the two-post rack | • 14U rack-mountable chassis; 27 in. to 31 in. and 22 in. rail kits for the four-post rack; mid-mount kit for the two-post rack |
Mounting | • Rack-mountable in a standard 19-inch EIA cabinet | • Rack-mountable in a standard 19-inch EIA cabinet |
Size | SNS5604 with airflow diversion rack-mount kit • Height: 40.00 cm (15.75 in., 9U) • Width: 43.74 cm (17.23 in.) • Depth: 61.29 cm (24.09 in.) | • Height: 61.23 cm (24.11 in., 14U) • Width: 43.74 cm (17.23 in.) • Depth: 61.04 cm (24.04 in.) |
System weight | • 24.5 kg (54 lb) for chassis • 68.95 kg (152.0 lb) for 192-port configuration, fully populated | • 35.61 kg (78.5 lb) for chassis • 145.8 kg (321.5 lb) for 384-port configuration, fully populated |
Model: OceanStor SNS5604
Detail: OceanStor SNS5604 6.1 Tbit/s Bandwidth per chassis (192 ports x 32 Gbit/s) data rate + 2.048 Tbit/s UltraScale ICL bandwidth (16 x 128 Gbit/s)
Availability: IN STOCK