Huawei OceanStor SNS5604 Directors are proven and dedicated network infrastructure products oriented to data centers’ mission-critical business.

Using Gen 6 Fiber Channel, Fabric Vision technology, and IO Insight, the directors deliver unmatched 32 Gbit/s performance, seamless scalability, and high reliability.

  • Enhance operational stability, maximize application performance, and increase business agility with enterprise-class Gen 6 directors which accelerate application response time by up to 71%
  • Provide “pay-as-you-grow” flexibility and Ports-on-Demand (PoD) capabilities for port expansion with a port rate up to 32 Gbit/s
  • Simplify end-to-end management of large-scale environments by automating monitoring and diagnostics, for simpler, flatter, low-latency fabrics

Huawei-OceanStor-SNS5604-front

Huawei-OceanStor-SNS5604-back

Model SNS5604 SNS5608
Number of Ports Up to 192 x 32 Gbit/s ports or a 256-port equivalent with 16 UltraScale ICL ports Up to 384 x 32 Gbit/s ports or a 512-port equivalent with 128 Gbit/s (4 x 32 Gbit/s) UltraScale ICL ports (32 Gbit/s x 4 QSFP ports)
Port Types FC32-48 port blade: F Port, E Port, EX Port, M Port, SIM, and D Port

SX6 Extension Blade: F Port, E Port, and EX Port on FC, and VE Port on GbE

Fiber Channel Blades FC32-48 port blade provides 48 ports of 32 Gbit/s Gen 6 Fiber Channel
Extension Blades SX6 Extension Blade provides Fiber Channel extension (16 x 32 Gbit/s Fiber Channel ports) and IP extension over IP networks (16 x 1/10 GbE and 2 x 40 GbE ports)
Scalability Full-fabric architecture of 239 switches
Chassis Bandwidth 6.1 Tbit/s per chassis (192 ports x 32 Gbit/s) data rate + 2.048 Tbit/s UltraScale ICL bandwidth (16 x 128 Gbit/s) 12.2 Tbit/s per chassis (384 ports x 32 Gbit/s) data rate + 4.096 Tbit/s UltraScale ICL bandwidth (32 x 128 Gbit/s)
Slot Bandwidth 1,536 Gbit/s (line rate)
Switch Latency FC32-48 blade at Gen 6 32 Gbit/s speeds: < 900 ns (including FEC); any-port-to-any-port local switching and 2.7 μs blade to blade at 32 Gbit/s, cut-through routing

SX6 blade, Fiber Channel to Fiber Channel: < 900 ns (including FEC) and 2.7 μs any-port-to-any-port at 32 Gbit/s, cut-through routing

Maximum Frame Size 2,112-byte payload
Frame Buffers 15,360 per switching ASIC

 OcesnStor SNS5604OcesnStor SNS5608
ChassisSingle chassis:
• Up to 192 32 Gbps(E, F, D, M, SIM, AE, and EX) Fibre Channel ports using 48-port 32 Gbps Fibre Channel blades.
• Up to 256-port equivalent with with 16 128 Gbps UltraScale ICL ports (4x32 Gbps QSFP ports).
Single chassis:
• Up to 384 32 Gbps(E, F, D, M, SIM, AE, and EX) Fibre Channel ports using 48-port 32 Gbps Fibre Channel blades.
• Up to 512-port equivalent with with 32 128 Gbps UltraScale ICL ports (4x32 Gbps QSFP ports).
Control processor• Redundant (active/standby) control processor modules• Redundant (active/standby) control processor modules
System processors• FreeScale P4080 (8 core), 1.5 GHz• FreeScale P4080 (8 core), 1.5 GHz
Scalability• Full-fabric architecture of 239 switches• Full-fabric architecture of 239 switches
Certified maximum• 6000 active devices per switch;
• 56 switches, 19 hops in Fabric OS fabrics;
• larger fabrics certified as required
• 6000 active devices per switch;
• 56 switches, 19 hops in Fabric OS fabrics;
• larger fabrics certified as required
Fibre Channel blades• FC32-48 port blade provides 48 ports of 32 Gbps Gen 6 Fibre Channel• FC32-48 port blade provides 48 ports of 32 Gbps Gen 6 Fibre Channel
Extension blades• SX6 Extension Blade provides Fibre Channel extension (16×32 Gbps Fibre Channel ports) and IP extension over IP networks (16×1/10 GbE and 2×40 GbE ports)• SX6 Extension Blade provides Fibre Channel extension (16×32 Gbps Fibre Channel ports) and IP extension over IP networks (16×1/10 GbE and 2×40 GbE ports)
Performance• line speed, full duplex(4, 8, 16, and 32 Gbps)
• Autosensing of 4, 8, 16, and 32 Gbps port speeds depending on SFPs used;
• 10 Gbps port speeds with dedicated SFPs.
• line speed, full duplex(4, 8, 16, and 32 Gbps)
• Autosensing of 4, 8, 16, and 32 Gbps port speeds depending on SFPs used;
• 10 Gbps port speeds with dedicated SFPs.
ISL Trunking• Frame-based trunking with up to eight 32 Gbps ports per ISL trunk;
• up to 256 Gbps per ISL trunk;
• Exchange-based load balancing across ISLs with DPS included in FOS.
• Frame-based trunking with up to eight 32 Gbps ports per ISL trunk;
• up to 256 Gbps per ISL trunk;
• Exchange-based load balancing across ISLs with DPS included in FOS.
UltraScale ICL trunking• Chassis-to-chassis linkage through connectors on the Core Routing (CR) blade
• Can configure the following maximum QSFPs per trunk depending on blade type, connecting:
- Up to four 4×32 Gbps QSFP ports in a trunk group to form a 512 Gbps trunk between two CR32-4 blades. For trunks containing four or fewer QSFP ports, ports in a trunk must be located in the same port group on each blade.
- Up to four 4×32 Gbps QSFP ports in a trunk group to form a 512 Gbps trunk between a Brocade CR32-4 and CR32-8 blade. For trunks containing four or fewer QSFP ports, ports in a trunk must be located in the same port group on each blade.
• A minimum of two QSFP connections are required for a trunk, and up to four 4×16 Gbps QSFP trunks between pairs of CR32-4 and CR16-4.
• Chassis-to-chassis linkage through connectors on the Core Routing (CR) blade
• Can configure the following maximum QSFPs per trunk depending on blade type, connecting:
- Up to four 4×32 Gbps QSFP ports in a trunk group to form a 512 Gbps trunk between two CR32-4 blades. For trunks containing four or fewer QSFP ports, ports in a trunk must be located in the same port group on each blade.
- Up to four 4×32 Gbps QSFP ports in a trunk group to form a 512 Gbps trunk between a Brocade CR32-4 and CR32-8 blade. For trunks containing four or fewer QSFP ports, ports in a trunk must be located in the same port group on each blade.
• A minimum of two QSFP connections are required for a trunk, and up to four 4×16 Gbps QSFP trunks between pairs of CR32-8 and CR16-8.
Multichassis with UltraScale ICL ports• Up to 4,608 non-blocking 32 Gbps Fibre Channel ports;
• UtraScale ICL ports (16 per 4-slot chassis, optical QSFP) connect up to nine chassis in a full mesh topology or up to 12 chassis in a core-edge topology.
• Up to 4,608 non-blocking 32 Gbps Fibre Channel ports;
• UtraScale ICL ports (32 per 8-slot chassis, optical QSFP) connect up to nine chassis in a full mesh topology or up to 12 chassis in a core-edge topology.
UltraScale ICL bandwidth• 2.048 Tbps; 16 UltraScale ICL ports provide the equivalent of 64 32 Gbps ports. Each UltraScale ICL port provides 128 Gbps bandwidth over a QSFP (32 Gbps×4) link.
• Frame-based trunking is enabled between four UltraScale ICLs. DPS distributes exchanges across all frame trunks.
• 4.096 Tbps; 32 UltraScale ICL ports provide the equivalent of 128 32 Gbps ports. Each UltraScale ICL port provides 128 Gbps bandwidth over a QSFP (32 Gbps×4) link.
• Frame-based trunking is enabled between four UltraScale ICLs. DPS distributes exchanges across all frame trunks.
Chassis bandwidth• 6.1 Tbps per chassis (192 ports×32 Gbps) data rate + 2.048 Tbps UltraScale ICL bandwidth (16×128 Gbps)• 12.2 Tbps per chassis (384 ports×32 Gbps) data rate + 4.096 Tbps UltraScale ICL bandwidth (32×128 Gbps)
Slot bandwidth• 1,536 Gbps (line rate)• 1,536 Gbps (line rate)
Local switching bandwidth• 1.5 Tbps for Brocade FC32-48: 48 ports × 32 Gbps (data rate)• 1.5 Tbps for Brocade FC32-48: 48 ports × 32 Gbps (data rate)
Switch latency• FC32-48 blade:
- Locally switched port latency <900 ns (including FEC)
- Blade-to-blade latency is 2.7 μs
• SX6 blade:
- Fibre Channel to Fibre Channel: <900ns (including FEC)
- Any-port-to-any-port latency is 2.7 μs
• FC32-48 blade:
- Locally switched port latency <900 ns (including FEC)
- Blade-to-blade latency is 2.7 μs
• SX6 blade:
- Fibre Channel to Fibre Channel: <900ns (including FEC)
- Any-port-to-any-port latency is 2.7 μs
Maximum frame size• 2112 byte payload• 2112 byte payload
Frame buffers• 15,000 per switching ASIC• 15,000 per switching ASIC
Classes of service• Class 2, Class 3, Class F (inter-switch frames)• Class 2, Class 3, Class F (inter-switch frames)
Fibre Channel port types• FC32-48 port blade: F_Port, E_Port, EX_Port, M_Port, SIM, and D_Port;
• SX6 Extension Blade: F_Port, E_Port, and EX_Port on FC, and VE_Port on GbE
• NOTE: Self-discovery is based on switch type (U_Port) with an optional port-type control
• FC32-48 port blade: F_Port, E_Port, EX_Port, M_Port, SIM, and D_Port;
• SX6 Extension Blade: F_Port, E_Port, and EX_Port on FC, and VE_Port on GbE
• NOTE: Self-discovery is based on switch type (U_Port) with an optional port-type control
Data traffic types• Fabric switches supporting unicast, multicast (255 groups), and broadcast• Fabric switches supporting unicast, multicast (255 groups), and broadcast
Media types• FC32-48 port blade: Supports hot-pluggable Brocade Fibre Channel SFP+ at 32 Gbps SWL/LWL and SFP+ at 16 Gbps SWL/LWL/ELWL, 10 Gbps SWL/LWL SFP
• SX6 Extension Blade: Supports hot-pluggable Brocade Fibre Channel SFP+ at 32 Gbps SWL/LWL; SFP+ at 16 Gbps SWL/LWL/ELWL; SFP at 10 Gbps FC SWL/LWL and Ethernet SFP+ at 1 GbE copper, 1 GbE 1000BASE-SX/LX/CWDM, SFP+ at 10 GbE SR/LR; SFP+ at 10 GbE tunable DWDM 80 km, and QSFP at 40 GbE SR4/LR4/ER4
• Core Routing (CR) blades,CR32-4: Support hot-pluggable Brocade Fibre Channel QSFP at 4×32 Gbps SWL, 4×16 Gbps SWL and 4×16 Gbps 2 km QSFP for ICL connections
• FC32-48 port blade: Supports hot-pluggable Brocade Fibre Channel SFP+ at 32 Gbps SWL/LWL and SFP+ at 16 Gbps SWL/LWL/ELWL, 10 Gbps SWL/LWL SFP
• SX6 Extension Blade: Supports hot-pluggable Brocade Fibre Channel SFP+ at 32 Gbps SWL/LWL; SFP+ at 16 Gbps SWL/LWL/ELWL; SFP at 10 Gbps FC SWL/LWL and Ethernet SFP+ at 1 GbE copper, 1 GbE 1000BASE-SX/LX/CWDM, SFP+ at 10 GbE SR/LR; SFP+ at 10 GbE tunable DWDM 80 km, and QSFP at 40 GbE SR4/LR4/ER4
• Core Routing (CR) blades, CR32-8: Support hot-pluggable Brocade Fibre Channel QSFP at 4×32 Gbps SWL, 4×16 Gbps SWL and 4×16 Gbps 2 km QSFP for ICL connections
USB• One USB port per control processor for firmware download, support save, and configuration upload or download• One USB port per control processor for firmware download, support save, and configuration upload or download
Fabric services
• Adaptive Networking (Traffic Isolation, QoS); BB credit recovery; Brocade Advanced Zoning (default zoning, port/WWN zoning, peer zoning, target-driven zoning, broadcast zoning); Dynamic Path Selection (DPS); Extended Fabrics; FDMI; FICON CUP; Flow Vision; Frame Redirection; FSPF; IPFC; ISL Trunking; Management Server; Monitoring and Alerting Policy Suite (MAPS); N_Port Trunking; NPIV; NTP v3; Port Fencing; Registered State Change Notification (RSCN); Reliable Commit Service (RCS); Simple Name Server• Adaptive Networking (Traffic Isolation, QoS); BB credit recovery; Brocade Advanced Zoning (default zoning, port/WWN zoning, peer zoning, target-driven zoning, broadcast zoning); Dynamic Path Selection (DPS); Extended Fabrics; FDMI; FICON CUP; Flow Vision; Frame Redirection; FSPF; IPFC; ISL Trunking; Management Server; Monitoring and Alerting Policy Suite (MAPS); N_Port Trunking; NPIV; NTP v3; Port Fencing; Registered State Change Notification (RSCN); Reliable Commit Service (RCS); Simple Name Server
Extension• Supports DWDM, CWDM, and FC-SONET devices; Fibre Channel, in-flight compression (Brocade LZO) and encryption (AES-GCM-256); BB credit recovery; FCIP, IP Extension, Adaptive Rate Limiting (ARL), data compression, Fast Write, read/write Tape Pipelining, QoS• Supports DWDM, CWDM, and FC-SONET devices; Fibre Channel, in-flight compression (Brocade LZO) and encryption (AES-GCM-256); BB credit recovery; FCIP, IP Extension, Adaptive Rate Limiting (ARL), data compression, Fast Write, read/write Tape Pipelining, QoS
FICON• FFICON cascading; support for lossless DLS; FICON CUP; Advanced Accelerator for FICON (IBM
z/OS Global Mirror and read/write Tape Pipelining)
• FFICON cascading; support for lossless DLS; FICON CUP; Advanced Accelerator for FICON (IBM
z/OS Global Mirror and read/write Tape Pipelining)
Fibre Channel ports• Up to 192 32-Gbps ports, universal (F_Port, E_Port, EX_Port, M_Port, D_Port, SIM Port, FICON)• Up to 384 32-Gbps ports, universal (F_Port, E_Port, EX_Port, M_Port, D_Port, SIM Port, FICON)
Classes of service• Class 2, Class 3, Class F (inter-switch frames)• Class 2, Class 3, Class F (inter-switch frames)
ANSI Fibre Channel protocol• FC-PH (Fibre Channel Physical and Signaling Interface standard)• FC-PH (Fibre Channel Physical and Signaling Interface standard)
Fabric initialization• Complies with FC-SW 5.0• Complies with FC-SW 5.0
IP Extension (IP over Fibre Channel)• Complies with FC-IP 2.3 of the FCA profile• Complies with FC-IP 2.3 of the FCA profile
Port to port latency• Local switching: 900 ns
• Blade to blade: 2.7 μs
• Local switching: 900 ns
• Blade to blade: 2.7 μs
Switching capacity• An aggregate switching capacity of 13.5 billion frames per second (for Class 2, Class 3, and Class F frames for a 384-port chassis)• An aggregate switching capacity of 13.5 billion frames per second (for Class 2, Class 3, and Class F frames for a 384-port chassis)
Architecture• Non-blocking shared memory;
• passive backplane;
• redundant active/passive control processor;
• redundant active/active core switching blades;
• redundant WWN card
• Non-blocking shared memory;
• passive backplane;
• redundant active/passive control processor;
• redundant active/active core switching blades;
• redundant WWN card
Chassis power• Two power supplies required for AC Low Line (100 VAC to 120 VAC).
• One power supply required for AC High Line (200 VAC to 240 VAC).
• The device ships with two power supplies. One provides system power, but both must be installed to provide power efficiency and 1+1 redundancy.
• Four power supplies required for AC Low Line (100 VAC to 120 VAC).
• Two power supplies required for AC High Line (200 VAC to 240 VAC).
• Device ships with three PSUs or empty (3 for 2+1 redundancy). Two provide system power, but four must be installed to provide power efficiency and 2+2 redundancy.
Cooling• Requires two fan tray assemblies. A failure condition is one failed fan from any fan tray.
• Each assembly contains two fans for a total of four. The system requires three of four functioning fans for operation in the SNS5604. One fan assembly can be hot-swapped and should be replaced immediately in the event of a failure.
• Requires three fan tray assemblies. A failure condition is one failed fan from any fan tray.
• Each assembly contains two fans for a total of six. The system requires five of six functioning fans for operation in the SNS5608. One fan tray assembly can be hot-swapped and should be replaced immediately in the event of a failure.
Airflow• Non-port-side intake to port-side exhaust or port-side intake to non-port-side exhaust options are available.• Non-port-side intake to port-side exhaust or port-side intake to non-port-side exhaust options are available.
Solution availability• Designed to provide 99.999 percent uptime capabilities;
• hot-pluggable redundant power supplies, fans, WWN cards, processors, core switching, port blades, and optics;
• online diagnostics;
• non-disruptive firmware download and activation
• Designed to provide 99.999 percent uptime capabilities;
• hot-pluggable redundant power supplies, fans, WWN cards, processors, core switching, port blades, and optics;
• online diagnostics;
• non-disruptive firmware download and activation
Management• HTTP, SNMP v1/v3 (FE MIB, FC Management MIB), SSH; Auditing, Syslog; Advanced Web Tools, Brocade Network Advisor SAN Enterprise or Brocade Network Advisor SAN Professional Plus; Command Line Interface (CLI); SMI-S compliant; RESTful API; trial licenses for add-on capabilities• HTTP, SNMP v1/v3 (FE MIB, FC Management MIB), SSH; Auditing, Syslog; Advanced Web Tools, Brocade Network Advisor SAN Enterprise or Brocade Network Advisor SAN Professional Plus; Command Line Interface (CLI); SMI-S compliant; RESTful API; trial licenses for add-on capabilities
Security• DH-CHAP (between switches and end devices), FCAP switch authentication, FIPS 140-2 L2-compliant, HTTPS, IPsec, IP filtering, LDAP with IPv6, OpenLDAP, Port Binding, RADIUS, user-defined Role-Based Access Control (RBAC), Secure Copy (SCP), Secure RPC, SFTP, SSH v2, SSL, Switch Binding, TACACS+, Trusted Switch• DH-CHAP (between switches and end devices), FCAP switch authentication, FIPS 140-2 L2-compliant, HTTPS, IPsec, IP filtering, LDAP with IPv6, OpenLDAP, Port Binding, RADIUS, user-defined Role-Based Access Control (RBAC), Secure Copy (SCP), Secure RPC, SFTP, SSH v2, SSL, Switch Binding, TACACS+, Trusted Switch
Management access• 10/100/1000 Ethernet (RJ-45) per control processor, in-band over Fibre Channel; serial port (RJ-45) and one USB per control processor module; DHCP/DHCPv6; call-home integration enabled through Brocade Network Advisor• 10/100/1000 Ethernet (RJ-45) per control processor, in-band over Fibre Channel; serial port (RJ-45) and one USB per control processor module; DHCP/DHCPv6; call-home integration enabled through Brocade Network Advisor
Diagnostics• IO Insight for IO monitoring; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; built-in flow generator; POST and embedded online/offline diagnostics, including environmental monitoring, FCping and Pathinfo (FC traceroute), flow mirroring, frame viewer, non-disruptive daemon restart, optics health monitoring, power monitoring, RAStrace logging, and Rolling Reboot Detection (RRD)• IO Insight for IO monitoring; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; built-in flow generator; POST and embedded online/offline diagnostics, including environmental monitoring, FCping and Pathinfo (FC traceroute), flow mirroring, frame viewer, non-disruptive daemon restart, optics health monitoring, power monitoring, RAStrace logging, and Rolling Reboot Detection (RRD)
Temperature• Operating: 0°C to 40°C (32°F to 104°F)
• Non-operating: –25°C to 70°C (–13°F to 158°F)
• Operating: 0°C to 40°C (32°F to 104°F)
• Non-operating: –25°C to 70°C (–13°F to 158°F)
Humidity• Operating humidity: 5% to 93% RH non-condensing at 40°C (104°F) with a maximum gradient of 10% per hour
• Non-operating humidity: 10% to 93% RH non-condensing at 70°C (158°F)
• Operating humidity: 5% to 93% RH non-condensing at 40°C (104°F) with a maximum gradient of 10% per hour
• Non-operating humidity: 10% to 93% RH non-condensing at 70°C (158°F)
Altitude• Up to 3,000 meters (9,842 feet)• Up to 3,000 meters (9,842 feet)
Shock• Operating: 10 g, 11 ms, half sine wave
• Non-operating: 20 g, 11 ms, half sine wave
• Operating: 10 g, 11 ms, half sine wave
• Non-operating: 20 g, 11 ms, half sine wave
Heat dissipation• 192-port configuration: Typical: 4,696 BTU/hr; Max: 8,139 BTU/hr
• Power consumed: Typical: 1,376 W; Max: 2,385 W
Note: Input power is at 200 VAC with full PSU redundancy.
• 384-port configuration: Typical: 8,836 BTU/hr; Max: 14,485 BTU/hr
• Power consumed: Typical: 2,589 W; Max: 4,244 W
Note: Input power is at 200 VAC with full PSU redundancy.
Operating noise• 64.2 dB• 68.2 dB
Vibration• Operating: 5 Hz to 10 Hz @ +5 db/Oct; 10 Hz to 200 Hz @ 0.0005 Grms; 200 Hz to 500 Hz @
–5 db/Oct; scale 0.05 Grms
• Non-operating: 3 Hz to 10 Hz @ +5 db/Oct; 10 Hz to 200 Hz @ 0.0065 Grms; 200 Hz to 500 Hz @ –5db/Oct; scale 1.12 Grms
• Operating: 5 Hz to 10 Hz @ +5 db/Oct; 10 Hz to 200 Hz @ 0.0005 Grms; 200 Hz to 500 Hz @
–5 db/Oct; scale 0.05 Grms
• Non-operating: 3 Hz to 10 Hz @ +5 db/Oct; 10 Hz to 200 Hz @ 0.0065 Grms; 200 Hz to 500 Hz @ –5db/Oct; scale 1.12 Grms
Availability• 99.9999% at 1 year• 99.9999% at 1 year
MTBF (hours)• 190,875• 127,718
MTTR (hours)• 1.0• 1.0
Supported power range• Input voltage
Standard AC input:
Range: 85 VAC to 264 VAC Auto-volt
Nominal: 100 VAC to 240 VAC
• Power
85 to 132 VAC: 1,450 W
180 to 264 VAC: 2,870 W
• Input voltage
Standard AC input:
Range: 85 VAC to 264 VAC Auto-volt
Nominal: 100 VAC to 240 VAC
• Power
85 to 132 VAC: 1,450 W
180 to 264 VAC: 2,870 W
In-rush current• 35 Amps maximum, peak• 35 Amps maximum, peak
Frequency• 50 Hz to 60 Hz (Nominal: 50 Hz to 60 Hz)• 50 Hz to 60 Hz (Nominal: 50 Hz to 60 Hz)
Enclosure• 8U rack-mountable chassis; 27 in. to 31 in. rail, 18 in. to 24 in. rail, and airflow diversion rack mount kits for the four-post rack; mid-mount kit for the two-post rack• 14U rack-mountable chassis; 27 in. to 31 in. and 22 in. rail kits for the four-post rack; mid-mount kit for the two-post rack
Mounting• Rack-mountable in a standard 19-inch EIA cabinet• Rack-mountable in a standard 19-inch EIA cabinet
SizeSNS5604 with airflow diversion rack-mount kit
• Height: 40.00 cm (15.75 in., 9U)
• Width: 43.74 cm (17.23 in.)
• Depth: 61.29 cm (24.09 in.)
• Height: 61.23 cm (24.11 in., 14U)
• Width: 43.74 cm (17.23 in.)
• Depth: 61.04 cm (24.04 in.)
System weight• 24.5 kg (54 lb) for chassis
• 68.95 kg (152.0 lb) for 192-port configuration, fully populated
• 35.61 kg (78.5 lb) for chassis
• 145.8 kg (321.5 lb) for 384-port configuration, fully populated

Model: OceanStor SNS5604

Detail: OceanStor SNS5604  6.1 Tbit/s Bandwidth per chassis (192 ports x 32 Gbit/s) data rate + 2.048 Tbit/s UltraScale ICL bandwidth (16 x 128 Gbit/s)

Availability: IN STOCK