The S5700-28C-HI-AC is advanced Ethernet switch based on new generation of high-performance hardware and Huawei Versatile Routing Platform (VRP). Koos 24 GE sadamad(10/100/1000Base-T), see tagab suure lülitusvõimsuse, high-density GE interfaces for users, besides, it can be equipped with multiple types of card modules and power modules to meet the different demands of users. All these features make the S5700-28C-HI-AC the best choice as an access switch on large and medium-sized campus networks or data centers and aggregation switch on small campus networks. The S5700-28C-HI-AC integrates many advanced technologies in terms of reliability, turvalisus, ja energiasääst, et aidata ettevõtte klientidel ehitada järgmise põlvkonna IT-võrk.
Kiired andmed
Joonis 1 shows the appearance of Huawei S5700-28C-HI-AC switch.
Toote kood | S5700-28C-HI-AC |
Sadamad | 24 × 10/100/1,000 Base-T pordid |
Laiendatud pesad | 1 extended slot |
Mälu (RAM) | 512 MB |
Välk | 64 MB |
MAC-aadressitabeli suurus | 32 MAC |
Alakaart on toetatud | 2 x 10 GE SFP+ Optional subcard
4 x 10 GE SFP+ Optional subcard 4 x 1,000 BASE-X |
Vajalik pinge | AC:
Nimipinge vahemik: 100V kuni 240 V, 50/60 Hz Maksimaalne pinge vahemik: 90V kuni 264 V, 50/60 Hz |
Toiteseade | Do double hot-swappable AC/DC power supplies |
Power Consumption Operational | <76 W |
Edastamine jõudlust | 96 Mpps |
Lülitusvõimsus | 256 Gbit / s |
Mõõtmed (L x S x K) | 442 mm x 220 mm x 43.6 mm |
Pakendi kaal | 5.1 kg |
PoE | Ei toetata |
Toote üksikasjad
Joonis 2 shows the front panel of HuaweiS5700-28C-HI-AC switch.
Märge:
① | Toitemooduli pesa 1 | ② | Toitemooduli pesa 2 |
③ | ESD pesa | ④ | Üks konsooliport |
⑤ | ETH haldussadam | ⑥ | USB-port |
⑦ | Kakskümmend neli 10/100/1000BASE-T porti | ⑧ | Esikaardi pesa |
*Enne lüliti paigaldamist või hooldamist, kandke ESD randmerihma ja sisestage ESD randmerihma teine ots sellesse ESD pesasse.
*The power module slot 1 and power module slot 2 have been installed with the AC power module, but the power module should be purchased separately.
Joonis 3 shows the back panel of Huawei S5700-28C-HI-AC.
Märge:
① | Maandatud kruvi |
③ | Seireport |
* The ground screw is used with a ground cable. The switch has two ground screws, any of which can be used to install a ground table.
* The monitoring port monitors the cabinet door, toitemoodul, battery power, and power supply of the air conditioner.
Recommended Modules
Tabel 2 shows the recommended modules.
Mudel | Kirjeldus | |
Toitemoodul | W0PSA1701 | 170W vahelduvvoolu toitemoodul(Used In HI Series) |
ES5M0PSD1700 | 170W alalisvoolu toitemoodul (Used In HI Series) | |
Optilised transiiverid | OMXD30000 | Optiline transiiver,SFP +, 10G,Mitmerežiimiline moodul(850nm,0.3km,LC) |
OSX010000 | Optiline transiiver,SFP +, 10G,Ühemoodiline moodul(1310nm,10km,LC) | |
eSFP-GE-SX-MM850 | 10GBase-USR optiline transiiver,SFP +, 10G,Mitmerežiimiline moodul(850nm,0.1km,LC) | |
SFP-GE-LX-SM1310 | Optiline transiiver, eSFP, ANNA, Mitmerežiimiline moodul(850nm,0.5km,LC) | |
SFP-GE-LX-SM1310 | Optiline transiiver, eSFP ,ANNA ,Ühemoodiline moodul(1310nm,10km,LC) | |
S-SFP-GE-LH40-SM1310 | Optiline transiiver, eSFP, ANNA, Ühemoodiline moodul(1310nm,40km,LC) | |
S-SFP-GE-LH40-SM1550 | Optiline transiiver, eSFP, ANNA, Ühemoodiline moodul(1550nm,40km,LC) | |
Vasktransiiverid | SFP-1000BaseT | 1000ALUS-T (RJ45) SFP elektriline moodul, Automaatsed läbirääkimised,100m |
Kaart | ES5D00X2SA00 | 2 10 Gig SFP + liidesekaart(used in S5700HI series) |
ES5D00X4SA00 | 4 10 Gig SFP + liidesekaart(used in S5700HI series) | |
ES5D00G4SC00 | 4 Gig SFP interface card(used in S5700HI series) |
Compare with Similar Item
Tabel 3 shows the comparison of HuaweiS5700-28C-HI, S5700-28C-HI-AC and S5700-28C-HI-24S.
Mudelid | S5700-28C-HI | S5700-28C-HI-AC | S5700-28C-HI-24S |
Fikseeritud sadamad | 24 x 10/100/1,000 Base-T | 24 x 10/100/1,000 Base-T | 24 x 100/1,000 Alus-X |
Laiendatud pesad | 1 extended slot | 1 pikendatud pesad | 1 pikendatud pesad |
Toiteallikas | Topelt vahetatav AC / DC | Topelt vahetatav AC / DC | Topelt vahetatav vahelduvvool |
Edastamise tulemuslikkus | 96 Mpps | 96 Mpps | 96 Mpps |
Lülitusvõimsus | 256 Gbit / s | 256 Gbit / s | 256 Gbit / s |
Energiatarve | <76W | <76W | <80W |
Spetsifikatsioonid
Üksus | S5700-28C-HI | S5700-28C-HI-24S | S5710-108C-PWR-HI |
---|---|---|---|
Fikseeritud sadamad | 24 x 10/100/1,000 Base-T | 24 x 100/1,000 Alus-X | 48 x 10/100/1,000 ALUS-T, 8 x 10 GE SFP + |
Laiendatud pesad | 1 extended slot: Optional subcard 1: 2 x 10 GE SFP+ Optional subcard 2: 4 x 10 GE SFP+ Optional subcard 3: 4 x 1,000 BASE-X | 3 front extended slots: Optional subcard 1: 16 x 10/100/1,000 ALUS-T Optional subcard 2: 16 x 1,000 BASE-X 1 rear extended slot: Optional subcard 1: 4 x 10 GE SFP + (no GE auto adaption) Optional subcard 2: 4 x 40 GE QSFP + |
|
MAC-aadressitabel | IEEE 802.1d vastavus 32K MAC-aadressi sisestused MAC-aadressi õppimine ja vananemine Staatiline, dünaamiline, ja musta augu MAC-aadressi sisestused Pakettide filtreerimine lähte-MAC-aadresside põhjal | IEEE 802.1d vastavus 456K MAC-aadressi sisestused MAC-aadressi õppimine ja vananemine Staatiline, dünaamiline, ja musta augu MAC-aadressi sisestused Pakettide filtreerimine lähte-MAC-aadresside põhjal |
|
VLAN | 4K VLAN-id Külaline VLAN ja hääl VLAN GVRP MUX VLAN VLAN-i määramine MAC-aadresside põhjal, protokollid, IP-alamvõrgud, poliitika, ja sadamad 1:1 ja N:1 VLAN-i kaardistamine | ||
Usaldusväärsus | RRPP rõnga topoloogia ja RRPP mitme eksemplari Smart Linki puu topoloogia ja Smart Linki mitme eksemplari, millisekundilise kaitse lülitamine SEP ERPS (G.8032) BFD OSPF-i jaoks, BFD IS-IS jaoks, BFD VRRP jaoks, ja BFD PIM-i jaoks Palun (IEEE 802.1d), RSTP (IEEE 802,1w), ja MSTP (IEEE 802.1s) BPDU kaitse, juurekaitse, ja silmusekaitse | ||
MPLS Features | MPLS L3VPN MPLS L2VPN (VPWS/VPLS) MPLS-TE MPLS QoS | ||
IP marsruutimine | Staatiline marsruutimine, RIPv1/v2, OSPF, ON-ON, BGP, ja ECMP | ||
IPv6 funktsioonid | Naabrite avastamine (ND) Tee MTU (PMTU) IPv6 ping, IPv6 jäljend 6to4 tunnel, ISATAPi tunnel, ja käsitsi konfigureeritud tunnel ACL-id, mis põhinevad lähte-IPv6-aadressil, sihtkoha IPv6 aadress, Kiht 4 sadamad, või protokolli tüüp IPv6 Static routing, RIPng, OSPFv3, IS-ISv6, BGP4+, ja ECMP | ||
Multisaade | IGMP v1/v2/v3 snooping and IGMP fast leave MLD v1/v2 snooping Multisaate edastamine VLAN-is ja multisaate replikatsioon VLAN-ide vahel Multisaadetise koormuse tasakaalustamine pagasiruumi liikmesadamate vahel Kontrollitav multisaade Sadamapõhine multisaadete liikluse statistika IGMPv1/v2/v3, MLDv1/v2, PIM-SM, PIM-DM, PIM-SSM, and MSDP | ||
QoS / ACL | Liidese poolt saadetud ja vastuvõetud pakettide määra piiramine Pakettide ümbersuunamine Sadamapõhine liikluspolitsei ja kahemäärane kolmevärviline CAR Eight queues on each port WRR, DRR, SEST, WRR + SEST, ja DRR + PQ queue scheduling algorithms WRED 802.1p prioriteedi ja DSCP prioriteedi ümbermärgistamine Pakettide filtreerimine kihil 2 kihile 4, kehtetute kaadrite filtreerimine lähte-MAC-aadressi alusel, sihtkoha MAC-aadress, lähte IP-aadress, sihtkoha IP-aadress, TCP / UDP pordi number, protokolli tüüp, ja VLAN-i ID Määrade piiramine igas järjekorras ja liikluse kujundamine sadamates | ||
Turvalisus | Kasutajaõiguste haldamine ja paroolikaitse DoS rünnaku kaitse, ARP rünnaku kaitse, ja ICMP rünnakukaitse IP-aadressi sidumine, MAC-aadress, liides, ja VLAN Sadamate isoleerimine, sadama turvalisus, ja kleepuv MAC Blackhole'i MAC-aadressi kirjed Õppinud MAC-aadresside arvu piiramine 802.1x autentimine ja kasutajaliidese arvu piiramine liidesel AAA autentimine, RADIUS-autentimine, HWTACACS + autentimine, ja NAC SSH v2.0 Hüperteksti edastamise protokoll on turvaline (HTTPS) Protsessori kaitse Must nimekiri ja lubatud nimekiri | ||
OAM | Hardware OAM: EFM OAM CFM OAM Y.1731 performance test (hardware-level delay and jitter detection) | Software OAM: EFM OAM CFM OAM Y.1731 performance test |
|
Haldus ja hooldus | iStack MAC-i sunniviisiline edastamine (MFF) Virtuaalse kaabli test SNMP v1 / v2c / v3 RMON Veebipõhine NMS Erineva tasemega süsteemilogid ja häired 802.3az EEE sFlow NetStream Dying gasp | ||
Töökeskkond | Töötemperatuur: 0 ℃ to 50 ℃ Suhteline niiskus: 5% kuni 95% (mittekondenseeruv) | ||
Sisendpinge | AC: Nimipinge vahemik: 100V to 240V AC, 50/60 Hz Maksimaalne pinge vahemik: 90V to 264V AC, 50/60 Hz DC: Nimipinge vahemik: –48V kuni –60V, DC Maximum voltage range: –36V kuni –72V, DC | ||
Mõõtmed (L x S x K) | 442 mm x 220 mm x 43.6 mm | 442 mm x 470 mm x 87.2 mm | |
Energiatarve | < 1,680W (Device: 240W, PoE: 1440W) |